Send Message

Hospital One Step HIV 1.2 rapid test cassette 99% Accurate

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE2934
Model Number: IHI-302
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 40 T/Kits
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Strip/ Cassette Specimen: Whole Blood, Serum/plasma
Accuracy: 99% Certificate: CE,ISO 13485
Storage: 2-30℃ Shelf Time: 24months
High Light:

hiv home testing kits

,

home drug test kits

Hospital One Step HIV Home Test Kits 99% Accurate HIV Test Strip / Cassette
Applications:
Used for the qualitative presumptive detection of antibodies to HIV in human whole blood, serum, or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HIV infection in Hospital, Clinical lab, physician office and other professional organizations
Description:

HIV is the etiologic agent of Acquired Immune Deficiency Syndrome (AIDS). The virion is surrounded by a lipid envelope that is derived from host cell membrane. Several viral glycoproteins are on the envelope. Each virus contains two copies of positive-sense genomic RNAs. HIV 1 has been isolated from patients with AIDS and AIDS-related complex, and from healthy people with high potential risk for developing AIDS.1 HIV 2 has been isolated from West African AIDS patients and from seropositive asymptomatic individuals.2 Both HIV 1 and HIV 2 elicit immune response.3 Detection of HIV antibodies in serum, plasma is the most efficient and common way to determine whether an
individual has been exposed to HIV and to screen blood and blood products for HIV.4 Despite the differences in their biological characteristics, serological activities and genome sequences, HIV 1 and HIV 2 show strong antigenic cross-reactivity.5,6 Most HIV 2 positive sera can be identified by using HIV 1 based serological tests.
The HIV 1.2 Rapid Test Cassette (Serum/Plasma) is a rapid test to qualitatively detect the presence of antibody to HIV 1 and/or HIV 2 in serum or plasma specimen. The test utilizes latex conjugate and multiple recombinant HIV proteins to selectively detect antibodies to the HIV 1.2 in serum or plasma.

How to use?

For IHI-302:

Allow the test, specimen, buffer and/or controls to reach room temperature
(15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2. Place the cassette on a clean and level surface.
For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25μL) to the specimen area, then add 1 drop of buffer (approximately 40μL),and start the timer, see illustration below.
3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
 
Hospital One Step HIV 1.2 rapid test cassette 99% Accurate 0
For IHI-401:
 
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it as soon as possible.
2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25μL) to the specimen area, then add 1 drop of buffer (approximately 40 μL ),and start the timer, see ilustration below.
For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50uL) to the specimen area, then add 2 drops of buffer (approximately 80μL), and start the timer. See ilustration below.
For Fingerstick Whole Blood specimen:
●To use a capillary tube: Fill the capillary tube and transfer approximately 50μL of fingerstick whole blood specimen to the specimen area of test dipstick, then add 2 drops of buffer (approximately 80 μL) and start the timer. See ilustration below.
●To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 50μL) to fall into the specimen area of test dipstick, then add 2 drops of buffer (approximately 80 μL) and start the timer. See ilustration below.
3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result
 
For IHI-402:
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Remove the test Cassette from the sealed pouch and use it as soon as possible.
2. Place the Cassette on a clean and level surface.
For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25 μL) to the specimen area, then add 1 drop of buffer (approximately 40 μL),and start the timer, see illustration below.
For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 μL) to the specimen area, then add 2 drops of buffer (approximately 80μL), and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
To use a capillary tube: Fill the capillary tube and transfer approximately 50 μL of fingerstick whole blood specimen to the specimen area of test Cassette, then add 2 drops of buffer (approximately 80 μL) and start the timer. See illustration below.
To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 50 μL) to fall into the specimen area of test Cassette, then add 2 drops of buffer (approximately 80 μL) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
 
Hospital One Step HIV 1.2 rapid test cassette 99% Accurate 1
 
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of HIV antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test cassette immediately and contact your local distributor.
 

 

Cat. No.

Product Description

Specimen

Format

Kit Size

Cut-Off

Status

IHI-302

HIV 1.2 Rapid Test Cassette

S/P

Cassette

40T

See Insert

NON-CE

IHI-401

HIV 1.2 Rapid Test Dipstick

WB/S/P

Dipstick

50T

See Insert

NON-CE

IHI-402

HIV 1.2 Rapid Test Cassette

WB/S/P

Cassette

40T

See Insert

NON-CE

IHI-402S

HIV 1.2 Rapid Test Cassette Singue Use Kit

WB

Cassette

1T

See Insert

NON-CE

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852