THC Convenient Pathological Analysis Equipments Fast Reading Iso Certificate

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DTH-P802/DTH-803/DTH-802
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25 Cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Oral Fluid
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 20 Ng/mL*, 50 Ng/mL Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

 

 THC Oral Fluid​ Drug Abuse Test Kits Convenient High Quality Fast Reading Diagnosis With CE

 

 

Application And Description:

 

The THC Rapid Test  (Oral fluid) is a rapid chromatographic immunoassay for the detection of 9-THC (THC parent) in human oral fluid at a cut-off concentration of 20ng/ml.
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrophotometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

 

How to use?

 

DIRECTIONS FOR CASSETTE USE

 
Allow the test cassette, oral fluid collector, collection chamber to reach room temperature (15-30°C) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Sample Extraction
① Take the oral fluid collector out of the sealed pouch and insert sponge end into the mouth. Actively swab the inside of the mouth for at least 3 minutes to collect oral fluid until the sponge becomes fully saturated. Gently press the sponge between the tongue and teeth to assist saturation. No hard spots should be felt on the sponge when saturated.Note: Full saturation of sponge is very important to get enough oral fluid for processing. Otherwise, false or invalid results may be observed.
② Take the collection chamber out of the sealed pouch and have it unscrewed. Remove the oral fluid saturated collector from the mouth and place it into the collection chamber. Press sponge fully against the strainer to release oral fluid to the arrowed point level and then screw it back tightly. Discard the collector.
③ Gently shake the collection chamber for 10 seconds and then leave it for 10 minutes.

THC Convenient Pathological Analysis Equipments Fast Reading Iso Certificate 0

2. Test Reaction
④ Take test cassette out from sealed pouch, place it on a clean and level surface.
⑤ Again gently shake the collection chamber for 10 seconds and snap the tip open, invert it and then transfer 3 drops of oral fluid specimen (approximately 120 µL) into specimen well(s) of the test cassette. Start the timer.
⑥ Wait for the colored line(s) to appear. Read results at 5 minutes. Do not read results after 15 minutes.
⑦ Apply a security seal over screw cap of the collection chamber and send to the laboratory for confirmation if necessary.
 

 

 

THC Convenient Pathological Analysis Equipments Fast Reading Iso Certificate 1

 

DIRECTIONS FOR DEVICE USE

 

Allow the test Midstream, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Remove the test device from the sealed pouch and use it within one hour.
2. Take off the device cap and insert the absorbent wick to the mouth, put it under the tongue to collect oral fluid until the control line appears.
3. Put the device cap back outside of the absorbent wick and lace the test midstream on a clean and level surface. See illustration below.
4. Read results at 10 minutes. Do not read results after 15 minutes.

THC Convenient Pathological Analysis Equipments Fast Reading Iso Certificate 2

 

 

 

 

INTERPRETATION OF RESULTS


(Please refer to the previous illustration)


NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Marijuana concentration is below the detectable level of 20ng/ml.


*NOTE: The intensity of the color in the test line region (T) may vary depending on the concentration of 9-THC (THC parent) present in the specimen. Therefore, any shade of color in the test line region (T) should be considered negative.


POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Marijuana concentration is above the detectable level of 30ng/ml.


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test cassette immediately and contact your local distributor.

 

 

 

 

 

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DTH-P802 Marijuana (THC) Parent Rapid Test Cassette Oral Fluid Cassette 25 T 20 ng/mL*, 50 ng/mL CE
DTH-802 Marijuana (THC) Rapid Test Cassette Oral Fluid Cassette 25 T 12 ng/mL, 20 ng/mL* CE
DTH-803 Marijuana (THC) Rapid Test Device Oral Fluid Device 25 T 50 ng/mL* CE
 

 