Accurate Alcohol Drug Of Abuse Multi Drug Rapid Test Cup Oral Fluid Detectable Level 0.02%

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DAL-801/DAL-802
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 20/50 Tests/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Oral Fluid
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 0.02% Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

 

Accurate Alcohol Drug of Abuse detectable level (0.02%) Convenient Diagnosis Test Kits Oral Fluid With CE

 

Application And Description:

 

Two-thirds of all adults drink alcohol. The blood alcohol concentration at which a person becomes impaired is variable dependent upon the individual. Each individual has specific parameters that affect the level of impairment such as size, weight, eating habits and alcohol tolerance. Inappropriate consumption of alcohol can be a contributing factor to many accidents, injuries, and medical conditions.
 

 

How to use?

 
Allow the pouched dipstick to equilibrate to room temperature (15-30°C) prior to testing.
1. Avoid from placing anything in the mouth for fifteen (15) minutes prior to beginning of the test. This includes non-alcoholic drinks, tobacco products, coffee, breath mints and food, etc.
2. Spit the saliva into the collection cup.
3. Open the foil package and remove the test dipstick. Observe the reactive pad on the end of the test dipstick. If the reaction pad has a blue color before applying saliva sample, do not use.
4. Saturate the reactive pad with saliva from collection cup or by applying saliva directly to the pad. (It usually takes 6-8 seconds to be saturated.) Start timer immediately after saliva application.
5. Read result at two (2) minutes. Compare the color of the reaction pad with the color chart on foil pouch to determine the relative blood alcohol level.

Accurate Alcohol Drug Of Abuse Multi Drug Rapid Test Cup Oral Fluid Detectable Level 0.02% 0

【DIRECTIONS FOR CASSETTE USE】
Allow the pouched Cassette to equilibrate to room temperature (15-30C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour.
2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect saliva for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.
3. Remove the collector from the mouth. Place saturated saliva collector into chamber and press sponge fully against the strainer to collect saliva. Discard the collector. Snap the cap shut on the collection tube.
4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of saliva (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.
5. Read the results in 3-5 minutes. Compare the color of the reaction pad and standard color card to determine the relative blood alcohol concentration.
 

Accurate Alcohol Drug Of Abuse Multi Drug Rapid Test Cup Oral Fluid Detectable Level 0.02% 1

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). A negative result indicates that the Synthetic Marijuana metabolite concentration is below the detectable level (25ng/mL).


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.

POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). A positive result indicates that the Alcohol concentration exceeds the detectable level (0.02%).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DAL-801 Alcohol Rapid Test Dipstick Oral Fluid Dipstick 50 T 0.02% CE
DAL-802 Alcohol Rapid Test Cassette Oral Fluid Cassette 25 T 0.02% CE

 