Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMDP-101/DMDP-102/DMDP-114
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 40T/Kit, 50T/Kit
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette/Strip/Panel Specimen: Urine
Kit Size: 40T/Kit, 50T/Kit Storage: 2-30℃
Cut-off: 1000 Ng/mL*, 500ng/mL, 300ng/mL Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

 

Easy to use Drug Abuse Test Kit Methy/lenedioxypyrovalerone (MD/PV)​ One Step Test Kit

 

Application And Description:  

 

3, 4-methy/lenedioxypyrovalerone (MD/PV) is a psychoactive recreational drug with stimulant properties which acts as a norepinephrine-dopamine reuptake inhibitor (NDRI).

MD/PV is the 3,4-methy/lenedioxy ring-substituted analog of the compound pyro/valerone, developed in the 1960s, which has been used for the treatment of chronic fatigue and as an anorectic, but caused problems of abuse and dependence.

 

How to use? 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Methy/lenedioxypyrovalerone MD/PV Drug Abuse Test Kit Accurate And High Sensitivity 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Methy/lenedioxypyrovalerone MD/PV Drug Abuse Test Kit Accurate And High Sensitivity 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Methy/lenedioxypyrovalerone MD/PV Drug Abuse Test Kit Accurate And High Sensitivity 2

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Methy/lenedioxypyrovalerone (MD/PV) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Methy/lenedioxypyrovalerone (MD/PV) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMDP-102 Methy/lenedioxypyrovalerone (MD/PV) Rapid Test Cassette Urine Cassette 40 T 1000 ng/mL*, 500ng/mL, 300ng/mL CE
DMDP-114 Methy/lenedioxypyrovalerone (MD/PV) Rapid Test Panel Urine Panel 40 T CE
DMDP-101 Methy/lenedioxypyrovalerone (MD/PV) Rapid Test Dipstick Urine Dipstick 50 T CE