High Sensitivity Methylenedioxypyrovalerone (MDPV) Drug Abuse Test Kit Accurate

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: ISO9000
Model Number: DMDP-101/DMDP-102/DMDP-114
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 40 Tests /box
Delivery Time: 5-10 days
Payment Terms: Ex works
Supply Ability: 2000ml/month
Format: Cassette/Strip/Panel Specimen: Urine
Kit Size: 40T/Kit Storage: 2-30℃
Cut-off: 1000 Ng/mL*, 500ng/mL, 300ng/mL Certificate: CE
High Light:

Synthetic Antigen

,

Purified Antigen

Easy to use Drug Abuse Test Kit Methylenedioxypyrovalerone (MDPV)​ One Step Test Kit

 

Application And Description:

 

3, 4-methylenedioxypyrovalerone (MDPV) is a psychoactive recreational drug with stimulant properties which acts as a norepinephrine-dopamine reuptake inhibitor (NDRI).

MDPV is the 3,4-methylenedioxy ring-substituted analog of the compound pyrovalerone, developed in the 1960s, which has been used for the treatment of chronic fatigue and as an anorectic, but caused problems of abuse and dependence.

 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

High Sensitivity Methylenedioxypyrovalerone (MDPV) Drug Abuse Test Kit Accurate 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

High Sensitivity Methylenedioxypyrovalerone (MDPV) Drug Abuse Test Kit Accurate 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

High Sensitivity Methylenedioxypyrovalerone (MDPV) Drug Abuse Test Kit Accurate 2

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Methylenedioxypyrovalerone (MDPV) concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Methylenedioxypyrovalerone (MDPV) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMDP-102 Methylenedioxypyrovalerone (MDPV) Rapid Test Cassette Urine Cassette 40 T 1000 ng/mL*, 500ng/mL, 300ng/mL CE
DMDP-114 Methylenedioxypyrovalerone (MDPV) Rapid Test Panel Urine Panel 40 T CE
DMDP-101 Methylenedioxypyrovalerone (MDPV) Rapid Test Dipstick Urine Dipstick 50 T CE