Send Message

CE Approved High Sensative AMP Amphetamine Drug Abuse Diagnostic Test In whole blood/serum/plasma

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: Cassette(DAM-402)
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 40 cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette Specimen: Whole Blood/serum/plasma
Kit Size: 40T/Kit Storage: 2-30℃
Color: White Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

CE and FDA Approved  High Sensative AMP Amphetamine Drug Abuse Diagnostic Test In whole blood/serum/plasma


Applications:

 

The AMP Rapid Test Cassette (whole blood/serum/plasma)is a lateral flow chromatographic immunoassay for the detection of Amphetamine in whole blood or serum or plasma at a cut-off concentration of 80ng/ml. This test will detect other related compounds, please refer to the
analytical Specificity table in this package insert.
This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmedanalytical result. Gas chromatographymass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 
Description:
 
Amphetamine is a Schedule II controlled substance available by prescription (Dexedrine®) and is also available on the illicit market. Amphetamines are a class of potent sympathomimetic agents with therapeutic applications. They are chemically related to the human body’s natural catecholamines: epinephrine and norepinephrine. Acute higher doses lead to enhanced stimulation of the central nervous system and induce euphoria, alertness, reduced appetite, and a sense of increased energy and power. Cardiovascular responses to Amphetamines include increased blood pressure and cardiac arrhythmias. More acute responses produce anxiety, paranoia, hallucinations, and psychotic behavior. The effects of Amphetamines generally last 2-4 hours following use, and the drug has a half-life of 4-24 hours in the body. About 30% of Amphetamines are excreted in the urine in unchanged form, with the remainder as hydroxylated and deaminated derivatives.
The AMP Rapid Test Device (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Amphetamines in urine. The AMP Rapid Test Cassette (Urine) yields a positive result when Amphetamines in urine exceed 1,000 ng/mL.
 
 
How to use? 
 

【DIRECTIONS FOR USE】
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30℃) before opening it. Remove the cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 full drop of serum or plasma (approximately 40 μL), then add 2 drops of buffer (approximately 80μL) to the specimen well of the cassette, and then start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not interpret the result after 10 minutes.
 

CE Approved  High Sensative AMP Amphetamine Drug Abuse Diagnostic Test In whole blood/serum/plasma 0

For whole blood specimen:
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2. Place the cassette on a clean and level surface.
For Venipuncture Whole Blood specimen:
 Hold the dropper vertically and transfer 1 drop of whole blood (approximately 40μL) to the specimen well, then add 2 drops of buffer (approximately 80μL), and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
 To use a capillary tube: Fill the capillary tube and transfer approximately 40μL of fingerstick whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer(approximately 80μL) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

CE Approved  High Sensative AMP Amphetamine Drug Abuse Diagnostic Test In whole blood/serum/plasma 1
 
 
INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the controlline region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the Amphetamine concentration is below the detectable cut-off level.


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the controlline region (C). No line appears in the test line region (T).This positive result indicates that the Amphetamine concentration exceeds the detectable cut-off level.


INVALID: Controlline fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for controlline failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852