Send Message

High Qualified Drug Abuse Test Kit ZOL Rapid Test Cassette/Dipstick/Panel in Urine

Basic Information
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE, FDA 510K
Model Number: Dipstick/Cassettte/Panel
Minimum Order Quantity: 500
Packaging Details: 50T/Kit
Supply Ability: 100 Million a year
Format: Dipstick Specimen: Urine
Kit Size: 50T/Kit Cut-Off: 50ng/mL
Color: White Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

A rapid test for the qualitative detection of Zolpidem in human urine. For professional in vitro diagnostic CE certified

 

 

Applications: 

 

The ZOL Rapid Test is a rapid chromatographic immunoassay for the detection of Zolpidem in human urine at the cut-off concentration of 50ng/ml. Please refer to Analytical Specificity table in this package insert for details on reactivity.

This assay provides only a qualitative, preliminary, analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

 

Description: 

 

Zolpidem (brand names Ambien, Ambien CR, Intermezzo, Stilnox, Stilnoct, Sublinox, Hypnogen, Zonadin, Sanval and Zolsana) is a prescription medication used for the treatment of insomnia and some brain disorders. It is a short-acting nonbenzodiazepine hypnotic of the imidazopyridine class that potentiates GABA, an inhibitory neurotransmitter, by binding to GABAA receptors at the same location as benzodiazepines. It works quickly, usually within 15 minutes, and has a short half-life of two to three hours.
Zolpidem may be detected in blood or plasma to confirm a diagnosis of poisoning in hospitalized patients, provide evidence in an impaired driving arrest, or to assist in a medico-legal death investigation. Blood or plasma Zolpidem concentrations are usually in a range of 30–300 μg/l in persons receiving the drug therapeutically, 100–700 μg/l in those arrested for impaired driving, and 1000–7000 μg/l in victims of acute overdosage. Analytical techniques, in general, involve gas or liquid chromatography.

 

How to use? 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

High Qualified Drug Abuse Test Kit ZOL Rapid Test Cassette/Dipstick/Panel  in Urine 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30℃) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

High Qualified Drug Abuse Test Kit ZOL Rapid Test Cassette/Dipstick/Panel  in Urine 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30℃) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

High Qualified Drug Abuse Test Kit ZOL Rapid Test Cassette/Dipstick/Panel  in Urine 2

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Zolpidem concentration is below the detectable cutoff level.

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Zolpidem concentration is above the detectable cutoff level.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DZO-102 Zolpidem(ZOL) Rapid Test Cassette Urine Cassette 40 T 50 ng/mL* CE
DZO-114 Zolpidem(ZOL) Rapid Test Panel Urine Panel 40 T CE
DZO-101 Zolpidem(ZOL) Rapid Test Dipstick Urine Dipstick 50 T

CE

 

 

Contact Details