Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsRapid Test Kit

AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time

I'm Online Chat Now
China Hangzhou AllTest Biotech CO.,LTD certification
China Hangzhou AllTest Biotech CO.,LTD certification
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time

AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time
AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time

Large Image :  AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time Get Best Price

Product Details:
Place of Origin: CHINA
Brand Name: AllTest
Certification: ISO13485
Model Number: cassette(ITOG-345/ITOG-445)
Payment & Shipping Terms:
Minimum Order Quantity: 500
Packaging Details: 25T/Kit
Supply Ability: 100 Million a year
Detailed Product Description
Format: Cassette Specimen: Whole Blood,serum,plasma(ITOG-445) Serum,plasma(ITOG-345)
Kit Size: 25T/Kit Cut-Off: See Insert
Storage: 2-30℃ Shelf Time: 24 Months
High Light:

lateral flow test strips

,

lateral flow assay

 

 

AllTest TORCH IgG Combo Rapid Test Cassette  24 months Shelf Time

 

 

Applications:

 

ToRCH IgG Combo Rapid Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of IgG antibodies to Toxoplasma gondii (Toxo), Rubella virus (Rubella), Cytomegalovirus (CMV), and Herpes simplex virus 1/2 (HSV 1/2) in whole blood, serum or plasma to aid in the diagnosis of ToRCH.

 

 

Description:

 

ToRCH is an acronym for a group of infectious diseases that, while infecting the pregnant women, may cause birth defects in their newborns.1 ToRCH stands for 4 different infections that can adversely affect the pregnant women and the fetus, newborn children including birth defects and often leading to abortion. The four infections are Toxomplasma gondii (A spirochete), Rubella (Virus), CMV – Cytomegalovirus (Virus), HSV 1/2 – Herpes Simplex Virus 1 and/or 2 (Virus). The infections usually cause few, if any, symptoms in the pregnant woman, but pose greater risks of serious birth defects for neonates. Infections caused by ToRCH – Toxoplasma, Rubella Virus, Cytomegalo Virus (CMV) and Herpes Simplex Virus (HSV) – is the major cause of BOH (Bad Obstetric History).2 Risks are severe, if the mother gets the infection in the first trimester as the baby's organs start to form in this stage. General symptoms include premature birth, growth retardation, neurological abnormalities, and damage of the eye, liver, heart and ear as well as bone lesions. Microcephaly, hydrocephaly, seizures and psychomotor retardation accompany these malformations.

The ToRCH IgG Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of IgG antibodies to Toxo, Rubella, CMV, and HSV 1/2 in whole blood, serum or plasma specimens.

 

 

How to use?

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

  • Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
  • Place the test cassette on a clean and level surface. Hold the dropper vertically, draw the specimen up to the Fill Line as shown in illustration below (approximately 10μl). Transfer the specimen to the each specimen well, then add 2 drops of buffer (approximately 80μl) and start the timer. See the illustration below.
  • Wait for the colored line(s) to appear. The result should be read at 15 minutes. Do not interpret results after 20 minutes.

 

AllTest TORCH IgG Combo Rapid Test Cassette ITOG -445 24 months Shelf Time 0

 

 

INTERPRETATION OF RESULTS

(Please refer to the illustration above)

 

POSITIVE:

Toxo Positive: *Two colored lines appear in the “Toxo” section. One line should be in the control line region (C) and another line should be in the test line region (T).

Rubella Positive: *Two colored lines appear in the “Rub” section. One line should be in the control line region (C) and another line should be in the test line region (T).

CMV Positive: *Two colored lines appear in the “CMV” section. One line should be in the control line region (C) and another line should be in the test line region (T).

HSV 1/2 Positive: *Two colored lines appear in the “HSV 1/2” section. One line should be in the control line region (C) and another line should be in the test line region (T).

*Note: The intensity of the color in test line region (T) will vary depending on the concentration of IgG antibodies present in the specimen. Therefore, any shade of color in test line region (T) should be considered positive.

 

NEGATIVE: One colored line appears in the control line region (C) of every section. Non-appearance of a visible line in the test line region (T) of any section is indicative of a negative test result for that specific section, viz. Toxo, Rub, CMV, and HSV 1/2.

 

INVALID: Control line fails to appear in any section. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

 

Contact Details
Hangzhou AllTest Biotech CO.,LTD

Contact Person: selina

Tel: +8615857153722

Send your inquiry directly to us