China    manufacturer

Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Arabic
Turkish
China good quality Custom Monoclonal Antibody on sale China good quality Hybridoma Monoclonal Antibody on sale
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

I'm Online Chat Now

CrP Rapid Test Dipstick Rapid Test Kits detecting CRP Semi - Quantitatively

Product Details:

Place of Origin:CHINA
Brand Name:AllTest
Certification:CE
Model Number:Dipstick

Payment & Shipping Terms:

Minimum Order Quantity:500
Packaging Details:10T/Kit
Supply Ability:100 Million a year
Detailed Product Description
Format: Dipstick Specimen: Whole Blood,serum,plasma
Kit Size: 10T/Kit Cut-Off: 10ug/mL
Storage: 2-30℃ Shelf Time: 24 Months

 

A rapid test for the diagnosis of myocardial infarction (MI) by detecting CRP Semi-quantitatively CE certified

 

Applications: 

 

The CrP Rapid Test Dipstick (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the Semi-quantitative detection of human CrP in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI). The cutoff of the test is 10 μg/ml.

 

 

Description: 

 

C-reactive Protein (CrP) in patient’s sera has been found in association with acute infections, necrotic conditions and a variety of inflammatory disorders. There is a strong correlation between serum levels of CrP and the onset of the inflammatory process. Monitoring the levels of CrP in patient’s sera indicates the effectiveness of treatment and the assessment of patient recovery. It is used in particular to differentiate bacterial infections from virus infections.

 

 

How to use? 

 

Bring tests, specimens, buffer, and/or controls to room temperature (15-30°C) before use.

  1. Remove the Test Dipstick from its sealed pouch, and place it on a clean, level surface. For best results, the assay should be performed within one hour.
  2. Open the tube with the diluted sample and put the test strip with the arrow pointing end into the liquid. Make sure to dip the test not beyond the line for the maximum immersion depth (Max line). Avoid in any case a direct wetting of the result area by spilling or dipping the test beyond MAX line.
  3. Leave the test for minimum 10 seconds in the diluted sample until the slightly pink-colored liquid front becomes visible in the result area.
  4. Take out the test dipstick and place it on a plain and non-absorbent surface. Alternatively, the test dipstick can remain in the tube. Start the timer as the test starts to run.
  5. As the test begins to run you will observe a colored liquid migrate along the membrane of the reaction area. Interpret results at 5 minutes. Please stick exactly to this time line to ensure correct semi-quantitative results.CrP Rapid Test Dipstick Rapid Test Kits detecting CRP Semi - Quantitatively

 

 

 

 

 

INTERPRETATION OF RESULTS

 

CrP Rapid Test Dipstick Rapid Test Kits detecting CRP Semi - QuantitativelyCrP Rapid Test Dipstick Rapid Test Kits detecting CRP Semi - Quantitatively

 

NOTE:

  1. The intensity of the color in the test region (T) may vary depending on the concentration of analytes present in the specimen. Therefore, any shade of color in the test region should be considered positive. Please note that this is a semi-quantitative test only, and cannot determine the concentration of analytes in the specimen.
  2. Insufficient specimen volume, incorrect operating procedure or expired tests are the most likely reasons for control line failure.

 