China    manufacturer

Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Arabic
Hindi
Turkish
Indonesian
Vietnamese
Thai
Bengali
Persian
Polish
China good quality Custom Monoclonal Antibody on sale China good quality Hybridoma Monoclonal Antibody on sale
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

I'm Online Chat Now

Influenza A+B Rapid Test Dipstick Lateral Flow Immunochromatographic Assays , Swab / Nasal Aspirate

Product Details:

Place of Origin:CHINA
Brand Name:AllTest
Certification:CE
Model Number:IIN-501

Payment & Shipping Terms:

Minimum Order Quantity:500
Packaging Details:25T/Kit
Supply Ability:100 Million a year
Detailed Product Description
Format: Dipstick Specimen: Swab / Nasal Aspirate
Kit Size: 20T/Kit Cut-Off: See Insert
Storage: 2-30℃ Shelf Time: 24 Months

A rapid test for the qualitative detection of Influenza A and Influenza B virus in nasal swab, throat swab or nasal aspirate specimens CE certified

 

 

Applications:

The Influenza A+B Rapid Test Dipstick is a rapid chromatographic immunoassay for the qualitative detection of influenza A and B antigens in nasal swab or throat swab or nasal aspirate specimens. It is intended to aid in the rapid differential diagnosis of influenza A and B viral infections.

 

 

Description:

Influenza (commonly known as ‘flu’) is a highly contagious, acute viral infection of the respiratory tract. It is a communicable disease easily transmitted through the coughing and sneezing of aerosolized droplets containing live virus.1 Influenza outbreaks occur each year during the fall and winter months. Type A viruses are typically more prevalent than type B viruses and are associated with most serious influenza epidemics, while type B infections are usually milder.

The gold standard of laboratory diagnosis is 14-day cell culture with one of a variety of cell lines that can support the growth of influenza virus.2 Cell culture has limited clinical utility, as results are obtained too late in the clinical course for effective patient intervention. Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) is a newer method that is generally more sensitive than culture with improved detection rates over culture of 2-23%.3 However, RT-PCR is expensive, complex and must be performed in specialized laboratories.

The Influenza A+B Rapid Test Dipstick (Swab/Nasal Aspirate) qualitatively detects the presence of Influenza A and/or Influenza B antigen in nasal swab or throat swab or nasal aspirate specimens, providing results within 15 minutes. The test uses antibodies specific for Influenza A and Influenza B to selectively detect Influenza A and Influenza B antigen in nasal swab, throat swab or nasal aspirate specimens.

 

 

How to use?

 

Allow the test, specimen, extraction buffer to equilibrate to room temperature (15-30°C) prior to testing.
1. Remove the test Dipstick from the sealed foil pouch and use it as soon as possible.Best results will be obtained if the assay is performed immediately after opening the foil pouch.
2. Place the Extraction Tube in the workstation. Hold the extraction reagent bottle upside down vertically. Squeeze the bottle and let the solution drop into the extraction tube freely without touching the edge of the tube. Add 10 drops of extraction reagent (Approx. 400μL) to the Extraction Tube. See illustration 1.
3. Place the swab specimen in the Extraction Tube. Rotate the swab for approximately 10 seconds while pressing the head against the inside of the tube to release the antigen in the swab. See illustration 2.
4. Remove the swab while squeezing the swab head against the inside of the Extraction Tube as you remove it to expel as much liquid as possible from the swab. Discard the swab in accordance with your biohazard waste disposal protocol. See illustration 3.
5. With arrows pointing down, place the dipstick into the tube of solution and then start the timer. If the procedure is followed correctly, the liquid should be below the maximum line (MAX) on the test dipstick. See the illustration
6. Wait for the colored line(s) to appear. Read the result at 15 minutes. Do not interpret the result after 20 minutes.
 
Influenza A+B Rapid Test Dipstick Lateral Flow Immunochromatographic Assays , Swab / Nasal Aspirate
 
 
 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

POSITIVE Influenza A:* Two distinct colored lines appear. One colored line should be in the control region (C) and another colored line should be in the Influenza A region (A). A positive result in the Influenza A region indicates that Influenza A antigen was detected in the sample.

 

POSITIVE Influenza B:* Two distinct colored lines appear. One colored line should be in the control region (C) and another colored line should be in the Influenza B region (B). A positive result in the Influenza B region indicates that Influenza B antigen was detected in the sample.

 

POSITIVE Influenza A and Influenza B:* Three distinct colored lines appear. One colored line should be in the control region (C) and two colored line should be in the Influenza A region (A) and Influenza B region (B). A positive result in the Influenza A region and Influenza B region indicates that Influenza A antigen and Influenza B antigen were detected in the sample.

 

*NOTE: The intensity of the color in the test line regions (A or B) will vary based on the amount of Flu A or B antigen present in the sample. So any shade of color in the test regions (A or B) should be considered positive.

 

NEGATIVE: One colored line appears in the control region (C). No apparent colored line appears in the test line regions (A or B).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

 

Contact Details
Hangzhou AllTest Biotech CO.,LTD

Tel:86-571-56267891

Fax:86-571-56267856

Contact Person: Mrs. Selina

Send your inquiry directly to us (0 / 3000)