Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsDrug Abuse Test Kit

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine

I'm Online Chat Now
China Hangzhou AllTest Biotech CO.,LTD certification
China Hangzhou AllTest Biotech CO.,LTD certification
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine
Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine

Large Image :  Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine Get Best Price

Product Details:
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE, FDA 510K
Model Number: DTZD-101/DTZD-102/DTZD-114
Payment & Shipping Terms:
Minimum Order Quantity: 500
Packaging Details: 40,50T/Kit
Supply Ability: 100 Million a year
Detailed Product Description
Format: Dipstick/Cassettte/Panel Specimen: Urine
Kit Size: 50T/Kit Cut-Off: 200ng/mL
Color: Yellow Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

 
A rapid test for the qualitative detection of Trazodone(TZD)  in human urine. For professional in vitro diagnostic CE certified

 

 

Applications: 

 

Trazodone is a triazolopyridine derivative which is used to treat major depressive disorder. It possesses antidepressant, and also some anxiolytic and hypnotic activity. The primary use of trazodone is the treatment of major depression. Data from open and double-blind trials suggest the antidepressant efficacy of trazodone is comparable to that of amitriptyline, doxepin, and mianserin. Also, trazodone showed anxiolytic properties, low cardiotoxicity, and relatively mild side effects. The half-life of trazodone in the initial phase is about 3–6 h and the half-life in the terminal phase is about 5–9 h. TZD is extensively metabolized with only about 1% of the dose excreted unchanged in urine after 24 hr. Around 70 to 75% of 14C-labelled trazodone was found to be excreted in the urine within 72 hours.

 

Description: 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30℃) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30℃) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30℃) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Accurate Trazodone TZD Drug Abuse 200 Ng / ML Rapid Cassette / Dipstick / Panel In Urine 2

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Trazodone(TZD) concentration is below the detectable cutoff level.

 

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Zolpidem concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DTZD-102 Trazodone(TZD) Rapid Test Cassette Urine Cassette 40 T 200 ng/mL CE
DTZD-114 Trazodone(TZD) Rapid Test Panel Urine Panel 40 T CE
DTZD-101 Trazodone(TZD) Rapid Test Dipstick Urine Dipstick 50 T

CE

 

 

 

Contact Details
Hangzhou AllTest Biotech CO.,LTD

Contact Person: selina

Tel: +8615857153722

Send your inquiry directly to us