Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml

I'm Online Chat Now
China Hangzhou AllTest Biotech CO.,LTD certification
China Hangzhou AllTest Biotech CO.,LTD certification
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml

Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml
Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml

Large Image :  Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml Get Best Price

Product Details:
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMD-X14
Payment & Shipping Terms:
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25 cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Detailed Product Description
Format: AllTest Specimen: Powder
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 1000ng/ml Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

 

Ketamine High Precision One Step Drug of Abuse Diagnosis Test Kit  1000ng/ml Test Panel Powder With CE

 

Application:

 

The Ketamine Rapid Test Panel is a rapid chromatographic immunoassay for the qualitative detection of Ketamine at a cut-off 1000ng/ml.
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

 

Description:  

 

Ketamine is a dissociative anesthetic developed in 1963 to replace PCP (Phencyclidine). While Ketamine is still used in human anesthesia and veterinary medicine, it is becoming increasingly abused as a street drug. Ketamine is molecularly similar to PCP and thus creates similar effects including numbness, loss of coordination, sense of invulnerability, muscle rigidity, aggressive / violent behavior, slurred or blocked speech, exaggerated sense of strength, and a blank stare. There is depression of respiratory function but not of the central nervous system, and cardiovascular function is maintained.
The Ketamine assay contained within the KET Rapid Test Panel yields a positive result when the KET concentration exceeds 1000ng/ml.

 

How to use?

 

Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1.Wipe with the panel over the surface in which the drugs are expected
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml 0


FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml 1

 

 

 

 

INTERPRETATION OF RESULTS
(Please refer to the illustration above)
Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml 2

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appear in the Test region (T). This negative result means that the concentrations in the sample are below the designated cut-off levels for a particular drug tested.


*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml 3

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the sample is greater than the designated cut-off for a specific drug.


Ketamine High Precision Rdt Kit One Step Drug Of Abuse Diagnosis 1000ng / Ml 4

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.