Highly Accuracy Meperidine MPRD Drug Abuse Test Kit With CE / ISO13485

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMPR-101/DMPR-102/DMPR-114
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette/Strip/Panel Specimen: Urine
Kit Size: 40T/Kit Storage: 2-30℃
Cut-off: 100 Ng/ml Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

 

 

One Step Drug Abuse Test Kit Meperidine (MPRD) OXY Diagnosis with CE / ISO13485

 

Applications And Description: 

 

Meperidine (also known as Pethidine, Pethidin, Meperidol and Dolantin) a phenylpiperidine derivative, is a synthetic opioid analgesic. Many of its pharmacologic properties and indications are similar to those of morphine, Meperidine is preferred to morphine for obstetric use because its rapid onset of action and shorter duration usually permit greater flexibility in maternal analgesia, possibly with less effect on neonatal respiration. Like other opioid drugs, pethidine has the potential to cause physical dependence or addiction. It may be more likely to be abused than other prescription opioids, perhaps because of its rapid onset of action. When compared with oxycodone, hydromorphone, and placebo, pethidine was consistently associated with more euphoria, difficulty concentrating, confusion, and impaired psychomotor and cognitive performance when administered to healthy vo
lunteers. The especially severe side effects unique to pethidine among opioids—serotonin syndrome, seizures, delirium, dysphoria, tremor—are primarily or entirely due to the action of its metabolite, norpethidine.

 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL)) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Highly Accuracy Meperidine MPRD Drug Abuse Test Kit With CE / ISO13485 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Highly Accuracy Meperidine MPRD Drug Abuse Test Kit With CE / ISO13485 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

Highly Accuracy Meperidine MPRD Drug Abuse Test Kit With CE / ISO13485 2

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Meperidine (MPRD) concentration is below the detectable cutoff level.

 

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Meperidine (MPRD) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMPR-102 Meperidine (MPRD) Rapid Test Cassette Urine Cassette 40 T 100 ng/mL CE
DMPR-114 Meperidine (MPRD) Rapid Test Panel Urine Panel 40 T CE
DMPR-101 Meperidine (MPRD) Rapid Test Dipstick Urine Dipstick 50 T CE