Send Message

β2 microglobul Test Use with Human whole blood /serum /plasma By Fiatest fluorescence Immunoassay Analyzer

Basic Information
Place of Origin: China
Brand Name: Fiatest
Certification: CE, ISO13485
Model Number: FI-BMG-402
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 25 Tests/kit box, 50 kit box/Carton
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette Specimens: Whole Blood, Serum,plasma
Kit Size: 10T/25T Certificate: CE,ISO 13485
Storage: 2-30℃ Test Range: 0.2~20 Mg/L
High Light:

lateral flow test strips

,

lateral flow diagnostics

A rapid test for measuring β2 microglobulin in whole blood /serum /plasma with the use of Fiatest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.
 
 

Application:

 

The β2MG Test (whole blood/Serum/Plasma) is a rapid chromatographic immunoassay for the quantitative detection of β2MG in whole blood or serum or plasma to aid in the diagnosis of Renal function.

 

Description:

 

β2 microglobulin also known as B2M is a relatively small molecular weight protein with a molecular weight of 11.8 kD. It is present in all nucleated cells except red blood cells and placental trophoblasts, especially in lymphocytes and monocytes, and plays an important role in its immune response. effect. The ability of tumor cells to synthesize
β2-MG is also very strong. It binds to the heavy chain as a light chain of HLA with a non-covalent bond. Due to its small molecular weight, it can pass through the glomerular filtration membrane. The filtered β2-MG is almost completely reabsorbed in the proximal tubules, and the absorption rate is 99.92%. The reabsorbed β2-MG is completely degraded in the renal tubules.
β2-MG measurement is a sensitive indicator for the diagnosis of proximal convoluted tubule injury. Blood β2-MG is elevated and urinary β2-MG is normal, mainly due to decreased glomerular filtration function, which is common in acute nephritis and renal failure. Blood β2-MG is normal and urinary β2-MG is elevated, mainly due to the obvious impairment of renal tubular reabsorption function, which is found in congenital proximal convoluted tubule function, Fanconi syndrome, and renal transplant rejection. In addition, there is a certain value in the diagnosis of tumors.
β2-MG can also be used for the diagnosis and treatment monitoring of kidney transplantation, diabetic nephropathy, gout kidney and some malignant tumors.

 

 

How to use?

 

Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.Allow the test cassette, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Turn on the Analyzer power. Then according to the need, select “standard test” or “Quick test” mode.
2. Remove the ID card and insert it into the Analyzer port.
3. Pipette 10μL of specimen into the buffer tube, then mix thoroughly.
4. Pipette 75μL diluted sample into the sample well. Start the timer at the same time.
5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer,Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode: After 10 minutes of adding sample,Insert the test cassette into the Analyzer and click "New test" immediately,The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click "New test" at the same time, The Analyzer will automatically countdown 10 minutes. After the countdown, the Analyzer will give the result at once.
 
β2 microglobul Test Use with Human whole blood /serum /plasma By Fiatest  fluorescence Immunoassay Analyzer 0

INTERPRETATION OF RESULTS
Results read by Fiatest TM Fluorescence Analyzer.
The result of tests for β2MG is calculated by Fiatest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer.
Working range of Fiatest TM β2MG is 0.2~20 mg/l.
Reference range: 0.8~2.2mg/l.

 

Catalogue Number Item Name Sample Test Range KIT size
FI-BMG-402 β2 Test Cassette WB/S/P 0.2~20 mg/L 10T/25T
 

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852