China    manufacturer

Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Arabic
Turkish
China good quality Custom Monoclonal Antibody on sale China good quality Hybridoma Monoclonal Antibody on sale
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

I'm Online Chat Now

H.pylori Antigen Convenient High sensitivity Rapid Test Reader Fast Reading with CE

Product Details:

Place of Origin:China
Brand Name:AllTest
Certification:CE, ISO13485
Model Number:IHP-R602

Payment & Shipping Terms:

Minimum Order Quantity:N/A
Price:Negotiation
Packaging Details:20cassette/box
Delivery Time:2-4 Weeks
Payment Terms:Ex works
Supply Ability:10 M tests/month
Detailed Product Description
Color: Blue Format: Cassette
Specimen: Feces Storage: 2-30°C
Shelf Time: 24months Certificate: CE

Aaccurate PSA Rapid Test Cassette Whole Blood / Serum / Plasma
 
Description: 
 
Prostate specific antigen (PSA) is produced by prostate glandular and endothelial cells. It is a single chain 
glycoprotein with a molecular weight of approximate 34 kDa.1 PSA exists in three major forms circulating in the
 serum. These forms are free PSA, PSA bound to α1 – Antichymotrypsin (PSA-ACT) and PSA complexed with 
α2–macroglobulin (PSA-MG).2
PSA has been detected in various tissues of the male urogenital system but only prostate glandular and 
endothelial cells secrete it. The PSA level in serum of healthy men is between 0.1 ng/mL and 2.6 ng/mL. It can
 be elevated in malignant conditions such as prostate cancer, and in benign condition such as benign prostatic 
hyperplasia and prostatitis. A PSA level of 3 to 10ng/ml is considered to be in the “gray-zone” and levels above
 10ng/ml are highly indicative of cancer.3 Patients with PSA values between 3-10ng/ml should undergo further
 analysis of the prostate by biopsy.
The prostate specific antigen test is the most valuable tool available for the diagnosis of early prostate cancer.
 Many studies have confirmed that the presence of PSA is the most useful and meaningful tumor marker known
 for prostate cancer and prostate infection of Benign Prostatic Hyperplasia (BPH).4
The PSA Prostate Specific Antigen Semi-Quantitative Rapid Test Device (Whole blood /Serum /Plasma) utilizes
 a combination of colloidal gold conjugate and anti-PSA antibodies to selectively detect total PSA in whole blood,
 serum or plasma. The test has a cut-off value of 3ng/ml and a reference value of 10ng/ml.
 
 
PRINCIPLE
 
The PSA Rapid Test Cassette (Whole Blood /Serum /Plasma) is a semi-quantitative, membrane based
 immunoassay for the detection of PSA in whole blood, serum or plasma. The membrane is pre-coated with 
PSA antibodies on the test line region. During testing, the specimen reacts with the particle coated with anti-PSA
 antibody. The mixture migrates upward on the membrane chromatographically by capillary action to react with
 anti-PSA antibodies on the membrane and generate a colored line. A test line (T) intensity weaker than the
 reference line (R) indicates that the PSA level in the specimen is between 3-10ng/ml. A test line (T) intensity 
equal or close to the reference line (R) indicates that the PSA level in the specimen is approximately 10ng/ml. 
A test line (T) intensity stronger than the reference line (R) indicates that the PSA level in the specimen is above
 10ng/ml. To serve as a procedural control, a colored line will always appear in the control line region (C) indicating
 that proper volume of specimen has been added and membrane wicking has occurred.
 
 
How to use? 
 
H.pylori Antigen Convenient High sensitivity Rapid Test Reader Fast Reading with CE
 
 
REAGENTS
 
The cassette contains PSA monoclonal antibody particles and PSA monoclonal antibody coated on the membrane.
 
Applications: 
 
The PSA Prostate Specific Antigen Semi-Quantitative Rapid Test Cassette (Whole Blood /Serum /Plasma) is a
 rapid chromatographic immunoassay for semi-quantitative detection of Prostate Specific Antigen in whole blood, 
serum or plasma.
 
Specifications

Model

A rapid test for the qualitative detection of Prostate Specific Antigen (PSA) in whole  blood, serum
 or plasma.For professional in vitro diagnostic use only.

Format

Strip, Cassette

Accuracy

99.2%

Shelf life

24months

Component

Test cassettes, Droppers, Package insert, Sample dilution tube

Specimen

Serum/Plasma/Blood

Storage

2-30°C

Read time

20 mins

Others

The kits can be made according to the customers' artwork or design

 
 
STORAGE AND STABILITY
 
Store as packaged at room temperature or refrigerated (2-30°C). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.
 