Send Message

Durable Self used Drug Abuse Test Kit MCAT Rapid Test Panel / Urine , CE Approval

Basic Information
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE
Model Number: DMCA-101/DMCA-102/DMCA-114
Minimum Order Quantity: 500
Packaging Details: 40T/Kit,50T/Kit
Supply Ability: 100 Million a year
Format: Cassette/Dipstick/Panel Specimen: Urine
Kit Size: 40T/Kit,50T/Kit Cut-Off: 500 Ng/mL
Color: White Storage: 2-30℃
High Light:

rapid diagnostic test kits

,

one step rapid test

A rapid test for the qualitative detection of Methcathinone in human urine CE certified

 

 

Applications:

 

The MCAT Rapid Test  is a rapid chromatographic immunoassay for the detection of methcathinone in urine at a cut-off concentration of 500ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.

This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

 

Description:

 

Methcathinone, is a monoamine alkaloid and psychoactive stimulant, a substituted cathinone. Methcathinone is a highly addictive drug, primarily psychologically addicting and most of the signs of addiction to the drug are emotional or psychological. It has been popularized and continues to be sold under misleading names such as "bath salts", "plant fertilizers" or "research chemicals", but it is actually a powerful psycho-stimulant used as a recreational drug. Effects of this drug typically last from 4 to 6 hours. It is used as a recreational drug due to its potent stimulant and euphoric effects and is considered to be addictive, with both physical and psychological withdrawal occurring if its use is discontinued after prolonged or high-dosage administration.

 

 

 

 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Durable Self used Drug Abuse Test Kit MCAT Rapid Test Panel / Urine , CE Approval 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Durable Self used Drug Abuse Test Kit MCAT Rapid Test Panel / Urine , CE Approval 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Durable Self used Drug Abuse Test Kit MCAT Rapid Test Panel / Urine , CE Approval 2

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the methcathinone concentration is below the detectable cut-off level.

*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.

POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the methcathinone concentration exceeds the detectable cut-off level.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMCA-102 Methcathinone(MCAT) Rapid Test Cassette Urine Cassette 40 T 500 ng/mL CE
DMCA-114 Methcathinone(MCAT) Rapid Test Panel Urine Panel 40 T CE
DMCA-101 Methcathinone(MCAT) Rapid Test Dipstick Urine Dipstick 50 T CE

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852