CE Certified Lateral Flow Immunochromatographic Assays Clostridium difficile GDH Rapid Test Cassette

Basic Information
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE
Model Number: ICDG-602
Minimum Order Quantity: 500
Packaging Details: 10T/Kit
Supply Ability: 100 Million a year
Format: Cassette Specimen: Feces
Kit Size: 10T/Kit Cut-Off: See Insert
Storage: 2-30℃ Shelf Time: 24 Months
High Light:

rapid test kit

,

diagnostic tests for infection

In vitro rapid diagnostic test for the detection of Clostridium difficile antigen in human feces CE certified

 

 

Applications:

 

The Clostridium difficile Rapid Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of Clostridium difficile GDH in the human feces specimen.

 

 

Description:

 

Clostridium difficile is an anaerobic bacteria acting as an opportunistic pathogen: it grows in the intestine when the normal flora has been altered by treatment with antibiotics. Toxinogenic strains of Clostridium difficile cause infections from mild-diarrhea to pseudomembranous colitis, potentially leading to death. Disease is caused by two toxins produced by toxinogenic strains of C.difficile: Toxin A (tissue-damaging enterotoxin) and Toxin B (cytotoxin). Some strains produce both toxins A and B, some others produce Toxin B only. The potential role of a third (binary) toxin in pathogenicity is still debated. The use of Glutamate Dehydrogenase (GDH) as an antigen marker of C.difficile proliferation has been shown to be very effective because all strains produce high amount of this enzyme. Clostridium difficile GDH Rapid Test Cassette allows the specific detection of C. difficile's GDH in stool specimen. Samples with a positive result should be investigated further to test for toxigenicity of the bacteria.

 

 

How to use?

 

Allow the test, specimen, stool collection buffer and/or control to equilibrate to room temperature (15-30°C) prior to testing.
1. To process fecal specimens:
For Solid Specimens:
Unscrew the cap of the specimen collection tube, then randomly stab the specimen collection applicator into the fecal specimen at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.
For Liquid Specimens:
Hold the dropper vertically, aspirate fecal specimens, and then transfer 2 drops of the liquid specimen (approximately 80 µL) into the specimen collection tube containing the extraction buffer.
Tighten the cap onto the specimen collection tube, then shake the specimencollection tube vigorously to mix the specimen and the extraction buffer. Leave the collection tube for reaction for 2 minutes.
2. Remove the test cassette from the foil pouch and use it as soon as possible. Best results will be obtained if the test is performed immediately after opening the foil pouch.
3. Hold the specimen collection tube upright and unscrew the cap of the specimen collection tube. Invert the specimen collection tube and transfer 3 full drops of the extracted specimen (approximately 120µL) to the specimen well (S) of the test cassette, then start the timer. Avoid trapping air bubbles in the specimen well (S). See illustration below.
4. Read the results at 10 minutes after dispensing the specimen. Do not read results after 20 minutes.
5. Note: If the specimen does not migrate (presence of particles), centrifuge the diluted sample contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S).of a new test cassette and start afresh following the instructions mentioned above.

CE Certified Lateral Flow Immunochromatographic Assays Clostridium difficile GDH Rapid Test Cassette 0

 

 

 

INTERPRETATION OF RESULTS

 

The results are to be interpreted as follows:

POSITIVE:* Two distinct colored lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of Adenovirus antigen present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

INVALID: Control line (C) fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor

Note: during the drying process, a very faint shadow may appear at the Test line position. It should not be regarded as a positive result.

 

 