Send Message

Test Cassette Quantitative Detection Of Ferritin In Human Serum Or Plasma

Basic Information
Place of Origin: China
Brand Name: FIATEST
Certification: CE
Model Number: FI-FER-302
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 10T/25T
Delivery Time: 2-4 Weeks
Payment Terms: L/C, T/T
Supply Ability: 10 M tests/month
Product Name: Quantitative Detection Of Ferritin In Human Serum Or Plasma , Ferritin Test Cassette Qualified: CE
Specimen: Serum/Plasma Reading Time: 5 Minutes
Pack: 10T/25T Measuring Range: 1-500ng/ml
Features 1: Fast Result (in 15 Minutes) Features 2: Simple Operation (Less Training Required)
Features 3: Analyzer Provides Trusted Results Features 4: Strict Quality Control Insures High Accuracy
High Light:

Ferritin Detection Test Kits

,

Ferritin Test Cassette

,

FIATESTTM Ferritin Test Cassette

Product Name: Quantitative Detection Of Ferritin In Human Serum Or Plasma , Ferritin Test Cassette
Specimen: Serum/Plasma
Pack: 10T/25T
Features 1: Fast Result (in 15 Minutes)
Features 3: Analyzer Provides Trusted Results
Qualified: CE
Reading Time: 5 Minutes
Measuring Range: 1-500ng/ml
Features 2: Simple Operation (Less Training Required)
Features 4: Strict Quality Control Insures High Accuracy

 

Quantitative Detection of ferritin in human serum or plasma , Ferritin Test Cassette

 

A Fluorescence immunoassay quantitative detection of ferritin in human serum or plasma with the use of FIATESTTM Fluorescence Immunoassay Analyzer.

For professional in vitro diagnostic use only.

 

 

【INTENDED USE】

 

The FIATESTTM Ferritin Test Cassette (Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of ferritin in human serum or plasma.

 

【SUMMARY】

 

Iron is one of the important trace metal elements necessary for the body. More than 90% of the iron in the body is combined with protein, and iron-containing protein has many important biological functions in the body .

Ferritin is the protein with the most iron content in the body, mainly found in the spleen, liver and bone marrow. About 66% of the body's ferritin is synthesized by hepatocytes. Ferritin is a globular protein that can be expressed in almost all types of cells, soluble in water, cytoplasm or plasma, and stable in both intracellular and extracellular fluids . There are two physiological types of ferritin, one is serum ferritin (SF); the other is intracellular ferritin.

 

Serum ferritin (SF) is an important clinical indicator that reflects the body's iron storage.
Decreased serum ferritin concentrations of < 15 ng/ml always indicate iron deficiency and can be the result of prior blood loss, pregnancy. It is also an acute phase reactant and marker of a variety of inflammations in the body, and can increase non-specifically (values> 400 ng/ml) in a variety of inflammatory states, including chronic kidney disease, rheumatoid arthritis, other autoimmune diseases, as well as acute infections and
malignant tumors Wait.

 

【PRINCIPLE】
 
The FIATESTTM Ferritin Test Cassette (Serum/Plasma) detects Ferritin based on Fluorescence Immunoassay. The sample moves through the strip from sample pad to absorbent pad. If the specimen contains Ferritin, it attaches to the fluorescent microspheres-conjugated anti-Ferritin antibodies. Then the complex will be captured by the capture antibodies coated on the nitrocellulose membrane (Test line). The concentration of Ferritin in the sample correlates linearly with the fluorescence signal intensity captured on the T line. According to the fluorescence intensity of the test and standard curve, the concentration of Ferritin in the sample can be calculated by FIATESTTM Analyzer.
 
【PRECAUTIONS】
 
1. For professional in vitro diagnostic use only.
2. Do not use after the expiration date indicated on the package. Do not use the test if the foil pouch is damaged. Do not reuse.
3. Avoid cross-contamination of specimens by using a new specimen collection container for each specimen obtained.
4. Do not eat, drink or smoke in the area where the specimens and tests are handled.
Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout the procedure and follow standard procedures for proper disposal of specimens. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
5. Do not interchange or mix reagents from different lots.
6. Humidity and temperature can adversely affect results.
7. Used testing materials should be discarded in accordance with local regulations.
8. Read the entire procedure carefully prior to any testing.
9. The FIATESTTM Ferritin Test Cassette should only be used with the FIATESTTM
 
Analyzer by approved medical professional

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852