Convenient Methylenedioxypyrovalerone MDPV Drug Abuse Test Kit ISO13485 Approved

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMDP-802/DMDP-803
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25 Cassette(Device)/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Oral Fluid
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 300 Ng/mL Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

 

Convenient And Accurate Oral Fluid​ Methylenedioxypyrovalerone (MDPV) Drug Abuse Diagnosis Fast Reading Test Kits With CE

 

 

Application And Description

 

3, 4-methylenedioxypyrovalerone (MDPV) is a psychoactive recreational drug with stimulant properties which acts as a norepinephrine-dopamine reuptake inhibitor (NDRI). It was first developed in the 1960s by a team at Boehringer Ingelheim. MDPV remained an obscure stimulant until around 2004 when it was reportedly sold as a designer drug.
MDPV is the 3,4-methylenedioxy ring-substituted analog of the compound pyrovalerone, developed in the 1960s, which has been used for the treatment of chronic fatigue and as an anorectic, but caused problems of abuse and dependence.
The MDPV Rapid Test Cassette (Oral Fluid) is a rapid oral fluid screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of 3, 4-methylenedioxypyrovalerone in oral fluid. The MDPV Rapid Test Cassette/Midstream (Oral Fluid) yields a positive result when 3,4-methylenedioxypyrovalerone in oral fluid exceeds 300ng/ml.

 

 

How to use?

 

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.
3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the collection tube.
4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.
5. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 1 hour.
6. Apply the security seal over screw cap and send to the laboratory for confirmation if necessary.

Convenient Methylenedioxypyrovalerone MDPV Drug Abuse Test Kit ISO13485 Approved 0

【DIRECTIONS FOR DEVICE USE】
Allow the test device, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Remove the test device from the sealed pouch and use it within one hour.
2. Take off the device cap and insert the absorbent wick to the mouth, put it under the tongue to collect oral fluid until the control line appears.
3. Put the device cap back outside of the absorbent wick and lace the test midstream on a clean and level surface. See illustration below.
4. Read results at 10 minutes. Do not read results after 15 minutes.

Convenient Methylenedioxypyrovalerone MDPV Drug Abuse Test Kit ISO13485 Approved 1

 

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). A negative result indicates that the Synthetic Marijuana metabolite concentration is below the detectable level (25ng/mL).


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). A positive result indicates that the Methylenedioxypyrovalerone (MDPV)  concentration exceeds the detectable level (300 ng/mL).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMDP-802 Methylenedioxypyrovalerone (MDPV) Rapid Test Cassette Oral Fluid Cassette 25 T 300 ng/mL* CE
DMDP-803 Methylenedioxypyrovalerone (MDPV) Rapid Test Device Oral Fluid Device 25 T 300 ng/mL* CE

 