Procalcitonin (PCT) Diagnostic Test Kit Easy Use By Novatrend fluorescence Immunoassay In Whole Blood/Serum /Plasma

Basic Information
Place of Origin: China
Brand Name: Novatrend
Certification: CE, ISO13485
Model Number: FI-PCT-402
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 10T/25T
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette Specimen: Whole Blood/Serum /Plasma
Kit Size: 10T/25T Storage: 2-30℃
Test Range: 0.1~50 Ng/ml Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

 

A rapid test for measuring Procalcitonin (PCT) in whole blood /serum /plasma with the use of Novatrend TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.
 
 

Application:

 

The PCT Test Cassette (Whole Blood/Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of human Procalcitonin in whole blood, serum or plasma as an aid in the diagnosis of inflammatory conditions.

 

Description:

 

Procalcitonin (PCT) is a small protein that comprises 116 amino acid residues with a molecular weight of approximately 13 kDa which was first described by Moullec et al. in 1984. PCT is produced normally in C-cells of the thyroid glands. In 1993, the elevated level of PCT in patients with systemic infection of bacterial origin was reported and PCT is now considered to be the main marker of disorders accompanied by systemic inflammation and sepsis. The diagnostic value of PCT is important due to the close correlation between PCT concentration and the severity of inflammation. It was shown that “inflammatory” PCT is not produced in C-cells. Cells of neuroendocrine origin are presumably the source of PCT during inflammation.

 

 

How to use?

 

Refer to Novatrend TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.
1. Turn on the Analyzer power. Then according to the need, select “Standard test” or “Quick test” mode.
2. Take out the ID card and insert it into the Analyzer ID Card Slot.
3. Serum or plasma: Pipette 50 μL serum or plasma into the buffer tube, mix the specimen and the buffer well.
Whole blood: Pipette 75 μL whole blood into the buffer tube; mix the specimen and the buffer well.
4. Pipette 75 μL diluted sample into the sample well of the cassette. Start the timer at the same time.
5. There are two test modes for Novatrend TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Novatrend TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode:After 15 minutes of adding sample,Insert the test cassette into the Analyzer and click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode:Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time. The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.
 
Procalcitonin (PCT) Diagnostic Test Kit Easy Use By Novatrend fluorescence Immunoassay In Whole Blood/Serum /Plasma 0
 
INTERPRETATION OF RESULTS
Results read by Novatrend TM Fluorescence Immunoassy Analyzer.
The result of tests for PCT is calculated by Novatrend TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Novatrend TM Fluorescence Immunoassay Analyze.
Linearity range of Novatrend TM PCT is 0.1-50 ng/mL.
Reference range: <0.1ng/ml.

 

Catalogue Number Item Name Sample Test Range KIT size
FI-PCT-402 PCT Test Cassette WB/S/P 0.1~50 ng/ml

10T/25T

 