Ease to use Methaqualone (MQL) Diagnosis Drug AbuseTest Cassette/Dipstick/Panel Kit With CE

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMQ-101/DMQ-102/DMQ-114
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 40 Tests/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette/Dipstick/Panel Specimen: Urine
Kit Size: 40T/Kit Storage: 2-30℃
Cut-off: 300 Ng/ml Certificate: CE
High Light:

one step rapid test

,

home drug test kits

 

Methaqualone Drug Abuse Test Kit 300ng/ml For  Diagnosis of MQL

 

 

Applications:

 

The MQL One Step Methaqualone Test  (Urine) is a rapid immunochromatographic assay for the qualitative detection of MQL in human urine.

 

Description: 

 

Methaqualone (Quaalude, Sopor) is a quinazoline derivative that was first synthesized in 1951 and found clinically effective as a sedative and hypnotic in 1956. It soon gained popularity as a drug of abuse and in 1984 was removed from the US market due to extensive misuse. It is occasionally encountered in illicit form, and is also available in Europeon countries in combination with diphenhydramine (Mandrax). Methaqualone is extensively metabolized in vivo principally by hydroxylation at every possible position on the molecule. At least 12 metabolites have been identified in the urine.

 

How to use? 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Ease to use Methaqualone (MQL)  Diagnosis Drug AbuseTest Cassette/Dipstick/Panel Kit With CE 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Ease to use Methaqualone (MQL)  Diagnosis Drug AbuseTest Cassette/Dipstick/Panel Kit With CE 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Ease to use Methaqualone (MQL)  Diagnosis Drug AbuseTest Cassette/Dipstick/Panel Kit With CE 2

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Methaqualone (MQL) concentration is below the detectable cutoff level.

 

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Methaqualone (MQL) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMQ-102 Methaqualone (MQL) Rapid Test Cassette Urine Cassette 40 T 300 ng/mL* CE
DMQ-114 Methaqualone (MQL) Rapid Test Panel Urine Panel 40 T CE
DMQ-101 Methaqualone (MQL) Rapid Test Dipstick Urine Dipstick 50 T CE

 

 