Brand Name: | AllTest |
Model Number: | DMQ-101/DMQ-102/DMQ-114 |
MOQ: | N/A |
Price: | Negotiation |
Payment Terms: | Ex works |
Supply Ability: | 10 M tests/month |
Methaqualone Drug Abuse Test Kit 300ng/ml For Diagnosis of MQL
Applications:
The MQL One Step Methaqualone Test (Urine) is a rapid immunochromatographic assay for the qualitative detection of MQL in human urine.
Description:
Methaqualone (Quaalude, Sopor) is a quinazoline derivative that was first synthesized in 1951 and found clinically effective as a sedative and hypnotic in 1956. It soon gained popularity as a drug of abuse and in 1984 was removed from the US market due to extensive misuse. It is occasionally encountered in illicit form, and is also available in Europeon countries in combination with diphenhydramine (Mandrax). Methaqualone is extensively metabolized in vivo principally by hydroxylation at every possible position on the molecule. At least 12 metabolites have been identified in the urine.
How to use?
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.
【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.
【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Methaqualone (MQL) concentration is below the detectable cutoff level.
*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.
POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Methaqualone (MQL) concentration is above the detectable cutoff level.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.
Cat. No. | Product Description | Specimen | Format | Kit Size | Cut-Off | Status |
DMQ-102 | Methaqualone (MQL) Rapid Test Cassette | Urine | Cassette | 40 T | 300 ng/mL* | CE |
DMQ-114 | Methaqualone (MQL) Rapid Test Panel | Urine | Panel | 40 T | CE | |
DMQ-101 | Methaqualone (MQL) Rapid Test Dipstick | Urine | Dipstick | 50 T | CE |