China    manufacturer

Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Arabic
Turkish
China good quality Custom Monoclonal Antibody on sale China good quality Hybridoma Monoclonal Antibody on sale
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

I'm Online Chat Now

HCV Rapid Test Kits High Specificity , rapid diagnostic test kits

Product Details:

Place of Origin:China
Brand Name:AllTest
Certification:CE, ISO13485
Model Number:IHC-402

Payment & Shipping Terms:

Minimum Order Quantity:N/A
Price:Negotiation
Packaging Details:20cassette/box
Delivery Time:2-4 Weeks
Payment Terms:Ex works
Supply Ability:10 M tests/month
Detailed Product Description
Specimen: Serum/Plasma Time Of Use: One Time Use Only
OEM: Available Format: Strip, Cassette, Uncut Sheet
Accuracy: 99.2% Sample: Available

 

HCV Rapid Test Kits with High Specificity , rapid diagnostic test kits

 

Applications:

 

The HCV Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibody to Hepatitis C Virus in whole blood, serum or plasma.

 

Description: 

 

Hepatitis C Virus (HCV) is a small, enveloped, positive-sense, single-stranded RNA Virus. HCV is now known to be the major cause of parenterally transmitted non-A, non-B hepatitis. Antibody to HCV is found in over 80% of patients with well-documented non-A, non-B hepatitis. Conventional methods fail to isolate the virus in cell culture or visualize it by electron microscope. Cloning the viral genome has made it possible to develop serologic assays that use recombinant antigens. Compared to the first generation HCV EIAs using single recombinant antigen, multiple antigens using recombinant protein and/or synthetic peptides have been added in new serologic tests to avoid nonspecific cross-reactivity and to increase the sensitivity of the HCV antibody tests.
The HCV Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid test to qualitatively detect the presence of antibody to HCV in a whole blood, serum or plasma specimen. The test utilizes colloid gold conjugate and recombinant HCV proteins to selectively detect antibody to HCV in whole blood, serum or plasma. The recombinant HCV proteins used in the test kit are encoded by the genes for both structural (nucleocapsid) and non-structural proteins.

 

 

How to use? 

 

Allow test cassette, specimen, and/or controls to equilibrate to room temperature (15- 30°C) prior to testing.


1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the cassette on a clean and level surface.
For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25 μl) to the specimen area, then add 2 drops of buffer (approximately 80 μl),and start the timer, see illustration below.
For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 μl) to the specimen area, then add 2 drops of buffer (approximately 80 μl), and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
· To use a capillary tube: Fill the capillary tube and transfer approximately 50 μl of fingerstick whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer (approximately 80 μl) and start the timer. See illustration below.

3. Wait for the colored line(s) to appear. The test result should be read at 10 minutes. Do not interpret the result after 20 minutes.
Note: It is suggested not to use the buffer, beyond 30 days after opening the vial.


 

HCV Rapid Test Kits High Specificity , rapid diagnostic test kits

 

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


POSITIVE: * Two distinct colored lines appear. One color line should be in the control region (C) and another color line should be in the test region (T).
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of HCV antibodies present in the specimen. Therefore, any shade of red in the test region should be considered positive.


NEGATIVE: One color line appears in the control region (C). No apparent red or pink line appears in the test region (T).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

Contact Details
Hangzhou AllTest Biotech CO.,LTD

Tel:86-571-56267891

Fax:86-571-56267856

Contact Person: Mrs. Selina

Send your inquiry directly to us (0 / 3000)