China    manufacturer

Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Arabic
Turkish
China good quality Custom Monoclonal Antibody on sale China good quality Hybridoma Monoclonal Antibody on sale
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

I'm Online Chat Now

Fast and Reliable Procalcitonin PCT Rapid Test Kits

Product Details:

Place of Origin:China
Brand Name:ALLTEST
Certification:CE, ISO13485
Model Number:CPC-402

Payment & Shipping Terms:

Minimum Order Quantity:N/A
Price:Negotiation
Packaging Details:10T/kit
Delivery Time:2-4 Weeks
Payment Terms:Ex works
Supply Ability:10 M tests/month
Detailed Product Description
Specimen: Blood/Serum/Plasma Feature: High Sensitivity, Specificity, And No Cross Reactivity
Format: Cassette Storage: 2-30℃
OEM: Available Accuracy: 99.2%
Kit Size: 10T/kit Cut-Off: 1 Ng/ml

 

PCT Rapid Test Cassette with High Precise / Accurate

 

 

Applications:

 

The PCT Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of Procalcitonin in serum or

plasma.

 


Description: 

 

Procalcitonin(PCT) is a small protein that comprises 116 amino acid residues with a molecular weight of 

approximately 13 kDa which was first described by Moullec et al. in 1984. PCT is produced normally in 

C-cells of the thyroid glands. In 1993, the elevated level of PCT in patients with a system infection of bacterial 

origin was reported and PCT is now considered to be the main marker of disorders accompanied by systemic

 inflammation and sepsis. The diagnostic value of PCT is important due to the close correlation between PCT

 concentration and the severity of inflammation. It was shown that “inflammatory” PCT is not produced in 

C-cells. Cells of neuroendocrine origin are presumably the source of PCT during inflammation.

 

 

How to use? 


Allow test cassette, specimen, buffer and/or controls to equilibrate to room temperature (15-30℃) prior to testing.
1. Remove the Test Cassette from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the Test Cassette on a clean and level surface.
For Serum or Plasma specimens:
Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25 μL) to the specimen well (S) of the Test Cassette, and add 1 drop of buffer (approximately 40 μL), then start the timer. See illustration below.
For Venipuncture Whole Blood specimens:
Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 μL) to the specimen well (S) of the Test Cassette, and add 1 drop of buffer (approximately 40 μL), then start the timer. See illustration below.

For Fingerstick Whole Blood specimens:
To use a capillary tube: Fill the capillary tube and transfer approximately 50 μL of fingerstick whole blood specimen to the specimen well (S) of the Test Cassette, then add 1 drop of buffer (approximately 40 μL) and start the timer. See illustration below.
3. Wait for the colored line is appeared. The result should be read at 15minutes. Do not interpret the result after 20 minutes.

Fast and Reliable Procalcitonin PCT Rapid Test Kits

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


POSITIVE:* Two distinct colored lines appear. One colored line should be in the control region (C) and another colored line should be in the test region (T).


*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of PCT antigen present in the specimen. Therefore, any shade of color in the test region (T) should be considered positive.


NEGATIVE: One colored line appears in the control region (C). No apparent colored line appears in the test region (T).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor.