Send Message

One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DDI-X14
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25 cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Powder
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 300ng/ml Certificate: CE
High Light:

rapid diagnostic test kits

,

one step rapid test

 

One Step High Sensitivity 200ng/ml Fast Reading Cotinine (COT) Drug of Abuse Diagnosis Test Kit Test Panel Powder With CE Mark 

 

Application:

 

The cotinine Rapid Test Panel is a rapid chromatographic immunoassay for the qualitative detection of cotinineat a cut-off 200ng/ml.
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

 

Description:  

 

Cotinine is the first-stage metabolite of nicotine, a toxic alkaloid that produces stimulation of the autonomic ganglia and central nervous system when in humans. Nicotine is a drug to which virtually every member of a tobacco-smoking society is exposed whether through direct contact or second-hand inhalation. In addition to tobacco, nicotine is also commercially available as the active ingredient in smoking replacement therapies such as nicotine gum, transdermal patches and nasal sprays.
The cotinine assay contained within the COT Rapid Test Panel yields a positive result when the COT concentration exceeds 200ng/ml.

 

How to use?

 

Test device (in closed pouches), samples, and controls should be brought to room temperature (15-30°C) prior to testing. Do not open pouches until ready to perform the assay.
Remove the test device from its protective pouch and label the device with patient’s identification or control label.
FOR SURFACES
1.Wipe with the panel over the surface in which the drugs are expected.
2. Take off the cap of supplied tube;
3. Fill all buffers from the supplied tube of buffer into the protection cover.
4. Insert the Multi Test slowly and carefully into the protection cover with buffer
5. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel 0

FOR SOLIDS
1. Open the tube and put the solid in to the buffer.
2. Close the tube with dropper and cap. Shake it a short time. Wait for 30 sec.
3. Take off the cap of supplied tube;
4. Fill all buffers with dissolved substances into the protection cover.
5. Insert the Multi Test slowly and carefully into the protection cover with buffer.
6. Wait for lines to appear on the membrane and read the results after 5 minutes and do not interpret the result after 10 minutes.

One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel 1

 

 

INTERPRETATION OF RESULTS
(Please refer to the illustration above)
One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel 2

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appear in the Test region (T). This negative result means that the concentrations in the sample are below the designated cut-off levels for a particular drug tested.


*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel 3

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the sample is greater than the designated cut-off for a specific drug.


One Step High Sensitivity 200ng / Ml Cotinine COT Drug Of Abuse Diagnosis Test Panel 4

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852