Send Message

Tramadol TML Fast Reading Drug Abuse Test Kit High Specificity And Accurate

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: Oral Fluid Device (DTM-802/DTM-803)
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 25 Device(Cassette)/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Oral Fluid
Kit Size: 25 T/Kit Storage: 2-30℃
Cut-off: 30 Ng/mL Certificate: CE
High Light:

rapid diagnostic test kits

,

home drug test kits

 

Oral Fluid Tramadol(TML) Convenient  Rapid Test -  High Quality Fast Reading Drug Abuse Test Kits Diagnosis With CE

 

 

Application And Description: 
 

Tramadol(TML) is a quasi-narcotic analgesic used in the treatment of moderate to severe pain. It is a synthetic analog of codeine, but has a low binding affinity to the mu-opioid receptors. Large doses of tramadol can develop tolerance and physiological dependency and lead to its abuse. Tramadol is extensively metabolized after oral administration. The Tramadol contained within the TML Rapid Test Panel yields a positive result when the TML concentration exceeds 30ng/ml.

 

 

How to use?

 
Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.
3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the collection tube.
4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.
5. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 1 hour.
6. Apply the security seal over screw cap and send to the laboratory for confirmation if necessary.

Tramadol TML Fast Reading Drug Abuse Test Kit High Specificity And Accurate 0
【DIRECTIONS FOR DEVICE USE】
Allow the test device, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Remove the test device from the sealed pouch and use it within one hour.
2. Take off the device cap and insert the absorbent wick to the mouth, put it under the tongue to collect oral fluid until the control line appears.
3. Put the device cap back outside of the absorbent wick and lace the test midstream on a clean and level surface. See illustration below.
4. Read results at 10 minutes. Do not read results after 1 hour.

Tramadol TML Fast Reading Drug Abuse Test Kit High Specificity And Accurate 1
 
 
INTERPRETATION OF RESULTS
(Please refer to the previous illustration)
NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Marijuana concentration is below the detectable level of 20ng/ml.
*NOTE: The intensity of the color in the test line region (T) may vary depending on the concentration of 9-THC (THC parent) present in the specimen. Therefore, any shade of color in the test line region (T) should be considered negative.
POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Marijuana concentration is above the detectable level of 30ng/ml.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test cassette immediately and contact your local distributor.
 
 
 
 

Cat. No.Product DescriptionSpecimenFormatKit SizeCut-OffStatus
DTM-802Tramadol(TML) Rapid Test CassetteOral FluidCassette25 T30 ng/mL*CE
DTM-803Tramadol(TML) Rapid Test DeviceOral FluidDevice25 T30 ng/mL*CE

 

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852