Drug Abuse Test Kit
Created with Pixso.

MTD Drug Abuse Test Kit , Medical One Step Rapid Diagnostic Test

MTD Drug Abuse Test Kit , Medical One Step Rapid Diagnostic Test

Brand Name: AllTest
Model Number: DMT-802/DMT-803
MOQ: N/A
Price: Negotiation
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Detail Information
Place of Origin:
China
Certification:
CE, ISO13485
Format:
AllTest
Specimen:
Oral Fluid
Kit Size:
25 T/Kit
Storage:
2-30℃
Cut-off:
30 Ng/mL
Certificate:
CE
Packaging Details:
25 Cassette(Device)/box
Supply Ability:
10 M tests/month
Highlight:

rapid diagnostic test kits

,

one step rapid test

Product Description

 

Oral Fluid​  (MTD) Convenient Drug Abuse Diagnosis Fast Reading Test Kits With CE

 

 

Application And Description:

 

is a narcotic analgesic prescribed for the management of moderate to severe pain and for the treatment of opiate dependence (, Vicodin, Percocet, morphine).
is a long acting pain reliever producing effects that last from twelve to forty-eight hours. Ideally, frees the client from the pressures of obtaining illegal , from the dangers of injection, and from the emotional roller coaster that most opiates produce. , if taken for long periods and at large doses, can lead to a very long withdrawal period. The withdrawals from are more prolonged and troublesome than those provoked by cessation, yet the substitution and phased removal of is an acceptable method of detoxification for patients and therapists.
The MTD assay contained within the Multi-Drug Rapid Test Cassette/Midstream yields a positive result when the MTD concentration in saliva exceeds 30ng/ml.

 

 

How to use?

 

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Remove the collector from the sealed pouch and insert the sponge end of the collector into the mouth. Actively swab the inside of the mouth and tongue to collect oral fluid for a total of 3 minutes until the sponge becomes fully saturated. Gentle pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.
3. Remove the collector from the mouth. Place saturated oral fluid collector into chamber and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the collection tube.
4. Place the test cassette on a clean and level surface. Unscrew cap cover from the collection tube. Invert the collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette and start the timer. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. See illustration below.
5. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not read results after 1 hour.

 MTD Drug Abuse Test Kit , Medical One Step Rapid Diagnostic Test 0

DIRECTIONS FOR DEVICE USE


Allow the test device, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1. Remove the test device from the sealed pouch and use it within one hour.
2. Take off the device cap and insert the absorbent wick to the mouth, put it under the tongue to collect oral fluid until the control line appears.
3. Put the device cap back outside of the absorbent wick and lace the test midstream on a clean and level surface. See illustration below.
4. Read results at 10 minutes. Do not read results after 1 hour.

 MTD Drug Abuse Test Kit , Medical One Step Rapid Diagnostic Test 1

 

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). A negative result indicates that the Synthetic Marijuana metabolite concentration is below the detectable level (25ng/mL).


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). A positive result indicates that the (MTD)  concentration exceeds the detectable level (30ng/mL).


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 
Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMT-802 (MTD) Rapid Test Cassette Oral Fluid Cassette 25 T 30 ng/mL* CE
DMT-803 (MTD) Rapid Test Device Oral Fluid Device 25 T 30 ng/mL* CE