Send Message

Breath Accurate​ Convenient Drug Abuse Test Kit Breath Alcohol Drug Of Abuse

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DAM-802/DAM-803
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 15T/20 T
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: AllTest Specimen: Breath
Kit Size: 15T/20 T Storage: 2-30℃
Cut-off: 0.08% Ng/mL Certificate: CE
High Light:

one step rapid test

,

home drug test kits

 

Breath Alcohol Drug of Abuse Breath​ Accurate​ Convenient Diagnosis Test Kits With CE

 

Application And Description:

 

The Breath Alcohol Test is for the semi-quantitative, rapid detection of alcohol in the exhaled breath. It indicates relative Blood Alcohol Concentration (BAC) at 0.02%, 0.04%, 0.05%, 0.06%, 0.08% or 0.10% cut-off levels. The test is based on a chemical reaction. Alcohol reacts with the crystals in the Test to produce a color change. The color change depends on the amount of alcohol in the breath.

 

 

How to use?

 
Wait 15 minutes after last alcohol intake or drink a glass of water before testing.
1. Bring the pouch to room temperature (15-30 °C or 59-86 °F) before opening. Remove the Test from the sealed pouch. Do not touch the Mouthpiece to avoid contamination.
2. Hold the middle of the Test. Firmly squeeze the Test to break the Inner Glass Tube. Perform the test as soon as possible to avoid the affects of humidity. Do not crush or bend the Test. Refer to the picture below.

Breath Accurate​ Convenient Drug Abuse Test Kit Breath Alcohol Drug Of Abuse 0

 
3. Breathe into the Test.
· For Breath Alcohol Test without blow bag:
· Hold the middle of the Test horizontally. Take a deep breath. Blow hard into the Mouthpiece, in the same direction as the Test Arrows. Blow hard in one continuous breath for 12 seconds.
Note: Failure to blow hard, or in one continuous breath for 12 seconds, may cause false results. Do not inhale while blowing into the Test. Refer to the illustration below. Shake the Test slightly to distribute the crystals evenly in the Test Window.
 
· For Breath Alcohol Test with blow bag:
· Insert the Test into the Air Seal Neck of the blow bag in the same direction as the Test Arrows. Roll the Test into the blow bag until the Test Window is completely covered. Ensure the End of the Test is past the Air Seal Neck of the blow bag. Refer to the illustration below.

Breath Accurate​ Convenient Drug Abuse Test Kit Breath Alcohol Drug Of Abuse 1

· Hold the middle of the Test horizontally. Take a deep breath. Blow hard into the Mouthpiece of the Test until the blow bag is completely inflated.
Note: Failure to blow hard, or to inflate the blow bag completely, may cause false results. Do not inhale while blowing into the Test.
· Remove the Test from the blow bag. Shake the Test slightly to distribute the crystals evenly in the Test Window.
 
4. Read results at 2 minutes by looking at the color of the majority of crystals. Do not read results after 5 minutes.

 
INTERPRETATION OF RESULTS

For best results, compare the crystals from the used Test to the crystals from an unused Test of same cut-off level.


NEGATIVE: Majority of the crystals remain yellow-orange. The relative BAC is below the cut-off level of the Test. The crystals may be lighter than the crystals from an unused Test.


POSITIVE: Majority of the crystals are green-blue. The relative BAC is at or above the cut-off level of the Test.

 
Cat. No.Product DescriptionSpecimenFormatKit SizeCut-OffStatus
DAL-902Breath Alcohol Test (With/Without Blow bag)BreathCassette15T/20 T0.08%CE

 
 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852