Tramadol TML Drug Abuse Test Kit High Qualified Rapid In Human Urine

Basic Information
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE, FDA 510K
Model Number: DTM-101/DTM-102/DTM-114
Minimum Order Quantity: 500
Packaging Details: 50T/Kit
Supply Ability: 100 Million a year
Format: Dipstick/Cassettte/Panel Specimen: Urine
Kit Size: 50T/Kit Cut-Off: 100 Ng/mL*, 200 Ng/mL, 300 Ng/mL
Color: Yellow Certificate: CE
High Light:

one step rapid test

,

home drug test kits

 
A rapid test for the qualitative detection of Tramadol (TML) in human urine. For professional in vitro diagnostic CE certified

 

 

Applications And Description:

 

Tramadol(TML) is a quasi-narcotic analgesic used in the treatment of moderate to severe pain. It is a synthetic analog of codeine, but has a low binding affinity to the mu-opioid receptors. Large doses of tramadol can develop tolerance and physiological dependency and lead to its abuse. Tramadol is extensively metabolized after oral administration. Approximately 30% of the dose is excreted in the urine as unchanged drug, whereas 60% is excreted as metabolites. The major pathways appear to be N- and O- demethylation, glucoronidation or sulfation in the liver.

 

How to use?

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

Tramadol TML Drug Abuse Test Kit High Qualified Rapid In Human Urine 0

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Tramadol TML Drug Abuse Test Kit High Qualified Rapid In Human Urine 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to
testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Tramadol TML Drug Abuse Test Kit High Qualified Rapid In Human Urine 2

 

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Tramadol (TML) concentration is below the detectable cutoff level.

 

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Zolpidem concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DTM-102 Tramadol (TML) Rapid Test Cassette Urine Cassette 40 T 100 ng/mL*, 200 ng/mL, 300 ng/mL CE
DTM-114 Tramadol (TML) Rapid Test Panel Urine Panel 40 T CE
DTM-101 Tramadol (TML) Rapid Test Dipstick Urine Dipstick 50 T CE