Send Message

3-in-1 Flourescence Immunoassay Test kits for Cardiac Troponin T Myoglobin and CK-MB cardiac disease

Basic Information
Brand Name: ALLTEST Novatrend Plus
Model Number: FI-AMIT-435
Minimum Order Quantity: N/A
Price: negotiation
Qualified: CE Time To Results: 15 Minutes
Sample Type: Whole Blood/Serum/Plasma/Tissue Storage: 4-30°C
Product Type: Diagnostic Test Kits Test Range: CTnT: 0.1-40 Ng/mL / MYO: 5-200 Ng/mL / CK-MB: 0.2-75 Ng/mL
Shelf Time: 24months Sensitivity: High
Kit Size: 10T/25T/Kit
High Light:

mouse monoclonal antibodies

,

mab antibodies

The Troponin T/Myoglobin/CK-MB(3 in 1)Test Cassette (Whole Blood/Serum/Plasma) is intended for in vitro quantitative determination of human cardiac Troponin T, Myoglobin and CK-MB in whole blood, serum or plasma as an aid in the diagnosis of Myocardial Infarction (MI).

SUMMARY

Myoglobin (MYO), Creatine Kinase MB (CK-MB) and cardiac Troponin T (cTnT) are proteins released into the bloodstream after cardiac injury. Myoglobin is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa.1 When muscle cells are damaged, Myoglobin is released into the blood rapidly due to its relatively small size. The level of Myoglobin increases measurably above baseline within 2-4 hours post-infarct, peaking at 9-12 hours, and returning to baseline within 24-36 hours.2,3 CK-MB is an enzyme also present in the cardiac muscle, with a molecular weight of 87.0 kDa.4 Creatine Kinase is a dimeric molecule formed from two subunits designated as “M” and “B”, which combine to form three different isoenzymes, CK-MM, CK-BB and CK-MB. CK-MB is the isoenzyme of Creatine Kinase most involved in the metabolism of cardiac muscle tissue.5 The release of CK-MB into the blood following an MI can be detected within 3-8 hours after the onset of symptoms. It peaks within 9 to 30 hours, and returns to baseline levels within 48 to 72 hours.6 Cardiac Troponin T(cTnT) is a structurally bound protein found in striated muscle cells with a molecular weight of 37kD.7 Troponin T is part of a three subunit complex comprising of Troponin I and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle.8 After acute myocardial infarction (AMI), serum cTnT levels are elevated 2 to 8 hours after onset, peak in 12-24 hours and can persist for up to 14 days.9 Thus providing for a longer window of detection for cardiac injury.

The combined detection of three myocardial injury markers including CK-MB, cTnT and myoglobin has better sensitivity and specificity, which makes the diagnosis more accurate. To achieve early diagnosis, early treatment, reduce missed diagnosis and timely risk stratification of patients.

The Troponin T/Myoglobin/CK-MB(3 in 1)Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of antibody coated particles and capture reagent to detect cardiac Troponin T, Myoglobin and CK-MB in whole blood, serum or plasma.

PRINCIPLE

The Troponin T/Myoglobin/CK-MB(3 in 1)Test Cassette (Whole Blood/Serum/Plasma) detects cardiac Troponin T, Myoglobin and CK-MB based on Fluorescence Immunoassay. The sample moves through the strip from sample pad to absorbent pad. If the specimen contains cTnT, Myoglobin or CK-MB, it attaches to the fluorescent microspheres-conjugated specific antibodies. Then the complex will be captured by the capture antibodies coated on the nitrocellulose membrane (Test line). The concentration of cTnT, Myoglobin and CK-MB in the sample correlates with the fluorescence signal intensity captured on the Test line. According to the fluorescence intensity of the test and product standard curve, the concentration of cTnT, Myoglobin and CK-MB in the sample can be calculated by FIATESTTM Analyzer to show cTnT, Myoglobin and CK-MB concentration in specimen.

REAGENTS

The test kit includes cTnT antibody coated fluorophores, Myoglobin antibody coated fluorophores, CK-MB antibody conjugated fluorophores and capture reagents coated on the membrane.

PRECAUTIONS

if the foil pouch is damaged. Do not reuse.

STORAGE AND STABILITY

SPECIMEN COLLECTION AND PREPARATION

Preparation

Sample Handling

Sample Dilution

MATERIALS

Materials Provided

• Test Cassettes • Specimen Collection Tubes with Buffer

• ID Card • Package Insert

Materials Required But Not Provided

• Timer • Centrifuge • FIATESTTM Fluorescence Immunoassay Analyzer

• Pipette

DIRECTIONS FOR USE

Refer to FIATESTTM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted at room temperature.

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30 °C) prior to testing.

Whole blood: Transfer 75 μL whole blood into the buffer tube with pipette; mix the specimen and the buffer well.

Quick test mode: Insert the test cassette into the Analyzer at 15 minutes after sample application, click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

“Standard test” mode: Insert the test cassette into the Analyzer immediately after sample application, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time, the Analyzer will automatically count down 15 minutes. After the countdown, the Analyzer will give the result at once.

INTERPRETATION OF RESULTS

Results read by FIATESTTM Fluorescence Immunoassay Analyzer.

The result of tests for cTnT, Myoglobin and CK-MB is calculated by FIATESTTM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of FIATESTTM Fluorescence Immunoassay Analyzer.

Linearity range of cTnT Test is 0.1-40 ng/mL.

Linearity range of Myoglobin Test is 5-200 ng/mL.

Linearity range of CK-MB is 0.2-75 ng/mL.

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852