Send Message

High Sensitivity LH / Luteinizing Hormone Rapid Test Kits CE ISO 13485

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: FLH-101/FLH-102/FLH-103
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: Strip:50 or 100pcs/box,8000pcs or 10000pcs/ctn Cassette: 25pcs or 40pcs/box,2000pcs/ctn Midstream: 20pcs/poly bag or 1pc/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Strip/cassette/midstream/ Uncut Sheet Specimen: Urine
Accuracy: 99% Certificate: CE ISO 13485
Storage: 2-30℃ Shelf Time: 24months
Highlight:

rapid diagnostic test kits

,

One Step Rapid Test

 
 

High Sensitivity LH / Luteinizing Hormone Rapid Test Kits CE ISO 13485

 

 

Applications:
 

One step LH Rapid Test (Urine) is a rapid visual immunoassay for the qualitative, presumptive detection of luteinizing hormone in human urine specimens,intended for use as an aid in the detection of ovulation


Description: 
 


The LH(luteinizing hormone) which is in the urine of normal woman will increase dramatically in the middle of the menstrual cycle. The LH increase triggers ovulation which is when the egg is released periodically from normal fertile woman. Ovulation will occur after 24-48 hours following a positive test.
Thistest is a rapid qualitative immunochromatographic assay to predict when there is a LH surge, and in turn, when you are likely to ovulate. The test unitizes the double antibody sandwich method. It’s easy to use and read with high accuracy and speed.
 

 

How to use?
 

Strip:

 

Determine the day you will begin testing using the “When to Start Testing Chart”.
1. Allow the test, urine specimen and/or controls to reach room temperature (15-30 °C) prior to testing.
2. Bring the pouch to room temperature before opening it. Remove the Dipstick test from the sealed pouch and use it within one hour.
3. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum
line (MAX) on the test dipstick when immersing the dipstick. See illustration below.
4. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

High Sensitivity LH / Luteinizing Hormone Rapid Test Kits CE ISO 13485 0

 

 

Cassette:

Determine the day you will begin testing using the “When to Start Testing Chart”.
1. Allow the test, urine specimen and/or controls to reach room temperature (15-30 °C) prior to testing.
2. Bring the pouch to room temperature before opening it. Remove the Cassette test from the sealed pouch and use it within one hour.
3. Place the test cassette on a clean and level surface. Hold the sample dropper vertically and transfer 3 drops of urine (approx.120ul)to the specimen well of the test
cassette, and then start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
4. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not interpret the result after 10 minutes.

 

High Sensitivity LH / Luteinizing Hormone Rapid Test Kits CE ISO 13485 1

 

Midstream:

Allow the test, urine specimen and/or controls to reach room temperature (15-30°C) prior to testing.
1. Determine the day to begin testing. (See the above section: “WHEN TO START TESTING”).
2. Bring the pouch to room temperature before opening it. Remove the test midstream from the sealed pouch and use it as soon as possible.
3. Take down the cap of the midstream, hold the midstream so as to place the absorbent tip in the urine stream or place the absorbent tip (≥2/3) in urine in a clean cup for at least 15 seconds. (see illustration below).
4. Cover the cap on the testing midstream, then lay down the products on a clean and stable desk with the test and control window face upwards, and then start the timer immediately.
5. As the test begins to work, you may notice a light colored flow moving across the test and control window. Read the result at 3 minutes. Do not interpret the result after 10 minutes.


 

High Sensitivity LH / Luteinizing Hormone Rapid Test Kits CE ISO 13485 2

 

 


INTERPRETATION OF RESULTS 
(Please refer to the illustration)
POSITIVE: Two lines are visible and the line in test line region (T) is the same as or darker than the line in the control line region (C). This indicates probable
ovulation in 24-36 hours.
NEGATIVE: Two lines are visible, but the line in the test line region (T) is lighter than the line in the control line region (C), or there is no line in the test line region (T). This indicates that no LH surge has been detected.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852