Whole blood/ Serum / Plasma PSA Rapid Test Kits For Clinical Lab / Home

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: ISO13485, CE0123
Model Number: Cassette(TPS-402)
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 0.5mg/tube 1mg/tube, 2mg/tube、5mg/tube、10mg/tube、20mg/tube、30mg/tube
Delivery Time: 5-10 days
Payment Terms: Ex works
Supply Ability: 2000mg/month
Format: Cassette Specimens: Whole Blood, Serum,plasma
Shelf Time: 24months Certificate: CE0123, ISO 13485
Storage: 2-30℃ Cut-off: 3-10ng/ml
Highlight:

recombinant antigen

,

recombinant gene

One Step Prostate Specific Antigen (PSA) Test Kit for the diagnosis of Prostate Cancer Risk

Applications:

 

The Rapid PSA test is an immunochromatography based one step in vitro test. It is designed for the rapid semi-quantitative determination of human prostate specific antigen (PSA) in the specimens

 

Description:

 

Prostate cancer is the one of the most common types of cancer found in man. The incidence of prostate cancer increases with age and accounts for a growing number of newly diagnosed patients. Prostate specific antigen (PSA) is produced primarily in the prostate gland and is secreted into the prostate ducts and at ejaculation serves to liquefy the seminal coagulum. Virtually all healthy males under 50 years of age have PSA concentration under 4.0 ng/ml. If PSA level is above 20 ng/ml, the patient most likely to have prostate cancer. Some studies indicated that elevated total PSA levels are found in serum from patients who have prostate cancer cells metastasized throughout their bodies. Other studies indicated that Free PSA, which can not foam a complex with serine protease tends to be more abundant in patients with benign prostatic hyperplasia. Rapid PSA test use antibodies which can equally recognize both free PSA and PSA-ACT complex

 

How to use?

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2. Place the cassette on a clean and level surface.
For Serum ,Plasma or Venipuncture Whole Blood specimens:
· Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 40ul) or 2 drops of venipuncture whole blood (approximately 80 ul) to the specimen well (S) of test cassette, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
· To use a capillary tube: Fill the capillary tube and transfer approximately 80 ul of fingerstick whole blood specimen to the specimen well (S) of test cassette, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.
· To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 80 ul) to fall into the specimen well (S) of test cassette, then add 1 drop of buffer (approximately 40 ul) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear*. Read results at 5 minutes. Do not interpret the result after 10 minutes.
*Note: if migration is not observed in the result window after 30 seconds, add one or two extra drops of buffer.
Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.

 

Whole blood/ Serum / Plasma PSA Rapid Test Kits For Clinical Lab / Home 0

 

INTERPRETATION OF RESULTS
 
(Please refer to the illustration above)
 
POSITIVE:* Three distinct colored lines appear. A test line (T) intensity weaker than the reference line (R) indicates a PSA level between 3-10 ng/ml. A test line (T) intensity equal or close to the reference line (R) indicates a PSA level of approximately 10ng/ml. A test line (T) intensity stronger than the reference line (R) indicates a PSA level more than 10ng/ml.
 
NEGATIVE: Color lines appear in both the control (C) and reference (R) regions. No apparent colored line appears in the test line region (T). This indicates a PSA level below 3ng/ml.
 
INVALID: Control line (C) or reference line (R) fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
TPS-402 PSA Rapid Test Cassette WB/S/P Cassette 10 T 3-10ng/mL