Format: | Cassette/Dipstick/Panel | Specimen: | Urine |
---|---|---|---|
Kit Size: | 40T/Kit Or 50T/Kit | Storage: | 2-30℃ |
Cut-off: | 100 Ng/mL, 150 Ng/mL, 300 Ng/mL* | Certificate: | CE |
Highlight: | one step rapid test,home drug test kits |
COC Coc/aine Drug Abuse Test Kits Urine Drug Strip Test Kits
Application:
The COC Rapid Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of Coc/aine metabolite, Benzoylecgonine, in human urine at a cut-off concentration of 150ng/mL. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.
Description:
Coc/aine is a potent central nervous system (CNS) stimulant and a local anesthetic. It is often self-administered by nasal inhalation, intravenous injection and free-base smoking. It is excreted in urine in a short time primarily as Benzoylecgonine. Benzoylecgonine, a major metabolite of Coc/aine, has a longer biological half-life (5-8 hrs) than Coc/aine (0.5-1.5 hrs), and can generally be detected for 24-48 hours after Coc/aine exposure
One Step Coc/aine Urine Test is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Coc/aine in urine. Test yields a positive result when Coc/aine in urine reaches 300ng/ml.
How to use?
Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.
【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.
【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Benzoylecgonine concentration is below the detectable level.
*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.
POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Benzoylecgonine concentration is above the detectable level .
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new Test Cassette. If the problem persists, discontinue using the Test Cassette immediately and contact your local distributor.
Cat. No. | Product Description | Specimen | Format | Kit Size | Cut-Off | Status |
DCO-102 | COC/AINE (COC) Rapid Test Cassette | Urine | Cassette | 40 T | 100 ng/mL, 150 ng/mL, 300 ng/mL* |
CE/FDA |
DCO-114 | COC/AINE (COC) Rapid Test Panel | Urine | Panel | 40 T | CE/FDA | |
DCO-101 | COC/AINE (COC) Rapid Test Dipstick | Urine | Dipstick | 50 T | CE/FDA |