Color: | Green | Format: | Cassette |
---|---|---|---|
Specimen: | Feces | Storage: | 2-30°C |
Shelf Time: | 24months | Certificate: | CE |
Highlight: | rapid diagnostic test kits,cancer diagnostic tests |
Applications:
The Transferrin/FOB and Hp/Hb Combo Rapid Test Cassette (Feces) is a rapid chromatographic immunoassay (non-invasive assay) for the qualitative detection of human hemoglobin, transferring and Haptoglobin(Hp)/Hemoglobin(Hb) complex in human feces specimens, which might be useful for the diagnosis of bleeding gastrointestinal disorders.
Description:
Colorectal cancer is cancer that occurs in the colon or rectum, and affects both men and women of all racial and ethnic groups, and is most often found in people aged 50 years or older. For men, colorectal cancer is the third most common cancer after prostate and lung cancers. For women, colorectal cancer is the third most common cancer after breast and lung cancers.
Fecal occult blood should be an important indicator in the diagnostic evaluation of patients with suspected gastrointestinal bleeding of any etiology, not just as an indication of colorectal cancer. The presence of human hemoglobin in feces is inadequate as a screening test for stomach cancer (upper gastrointestinal disorders), because of human hemoglobin derived from the upper digestive tract is broken down in the intestinal tract (the antigenicity is lost).
Detection of fecal transferrin, which is more stable in stool than hemoglobin, provides an alternative way of diagnosing the disease in the upper digestive tract.
Blood in the stool may be the only symptom of cancer, but not all blood in the stool is caused by cancer. Other conditions that can cause blood in the stool include: Haemorrhoids, Anal fissures, Colon polyps, Peptic ulcers, Ulcerative colitis. Gastroesophageal reflux disease (GERD). Crohn's disease, use of non-steroidal anti-inflammatory drugs (NSAIDs).
The Haptoglobin/Hemoglobin Complex Rapid Test immunological test based on the detection of the hemoglobin-haptoglobin(Hb-Hp) complex. Meguro, who also found excellent sensitivity and fecal extracts the Hb/Hp complex was more stable than unbound hemoglobin. Thus, in patients with proximal colorectal bleeding, the Hb/Hp complex could probably be detectable in stool, even after a longer passage.
How to use?
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
Collect sufficient quantity of feces (1-2ml or 1-2g) in a clean, dry specimen collection container to obtain maximum antigens (if present). Best results will be obtained if the assay is performed within 6 hours after collection. Specimen collected may be stored for 3 days at 2-8℃ if not tested within 6 hours. For long term storage, specimens should be kept below -20℃.
• For Solid Specimens:
Unscrew the cap of the specimen collection tube,then randomly stab the specimen collection applicator into the fecal specimen in at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.
• For Liquid Specimens:
Hold the dropper vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 80μL) into the specimen collection tube containing the extraction buffer.
Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 120μL of supernatant, dispense into the specimen well (S) of a new test cassette and start afresh following the instructions mentioned above.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
Transferrin POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the Transferrin line region (Tf).
FOB POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the FOB line region (FOB).
FOB and Transferrin POSITIVE:* Three lines appear. One colored line should be in the control line region (C) and another two lines appear in the FOB and Tf regions.
Hp/Hb Complex Positive* Two line appear. One colored line should be in the control line region (C) and another apparent colored line should be in the Haptoglobin/Hemoglobin line region (Hp/Hb).
*NOTE: The intensity of the color line in the FOB, Tf and Hp/Hb complex line region will vary depending on the concentration of human hemoglobin and/or human transferring and/or Hp/Hb complex present in the specimen. Therefore, any shade of color in the FOB and/or Tf and/or Hp/Hb region should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the FOB, Tf and Hp/Hb region.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Cat. No. | Product Description | Specimen | Format | Kit Size | Cut-Off | Status |
TTFH-635 | Transferrin/FOB and Hb-Hp Combo Rapid Test Cassette | Feces | Cassette | 25 T | See Insert | CE |