Hangzhou AllTest Biotech CO.,LTD 

      Your Reliable Rapid Test Partner!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsAccuate Cardiac Marker Rapid Test kits

CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette

I'm Online Chat Now
China Hangzhou AllTest Biotech CO.,LTD certification
China Hangzhou AllTest Biotech CO.,LTD certification
I like the products and service provided by AllTest. They really take our interest into consideration.

—— Mr John Smith England

My oldest daughter actually has Lyme disease. She spent almost 1 year in a wheelchair because of Lyme. She is doing very well now. I used 2 of the samples. 1 to test my Lyme diagnosed daughter and 1 to test my daughter who does not have Lyme. Your tests worked well. My daughter with Lyme tested positive and the one who does not tested negative.

—— Ms Sheila

Whenever I have the requests,AllTest always give me the satisfied reply at the first time.

—— Mrs Julie Tschetter Belgium

As the old customer of AllTest since 2009, we should thank the great work have been done by AllTest to support us gain more market share and profit

—— Mr Robin Seifert Germany

CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette

CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette
CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette

Large Image :  CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette Get Best Price

Product Details:
Place of Origin: CHINA
Brand Name: AllTest
Certification: CE
Model Number: cassette
Payment & Shipping Terms:
Minimum Order Quantity: 500
Packaging Details: 10 tests per kit
Supply Ability: 100 Million a year
Detailed Product Description
Color: Red Format: Cassette(CBN-402)
Specimen: Whole Blood/Serum/Plasma Storage: 2-30°C
Shelf Time: 24months Certificate: CE
Cut-off: 0.45 Ng/ml
High Light:

rapid diagnostic test kits

,

cancer diagnostic tests

A rapid test for the diagnosis of myocardial infarction (MI) to detect NT-proBNP qualitatively in whole blood, serum or plasma CE certified

 

 

Applications:

 

The NT-proBNP Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human NT-proBNP in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).

 

 

Description:

 

The N-terminal of the prohormone brain natriuretic peptide (NT-proBNP) is a 76 amino acid N-terminal inactive protein that is cleaved from proBNP to release brain natriuretic peptide.Both BNP and NT-proBNP levels in the blood are used for screening, diagnosis of acute congestive heart failure (CHF) and may be useful to establish prognosis in heart failure, as both markers are typically higher in patients with worse outcome.The plasma concentrations of both BNP and NT-proBNP are also typically increased in patients with asymptomatic or symptomatic left ventricular dysfunction and is associated with coronary artery disease and myocardial ischemia.

The NT-proBNP Rapid Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of anti-NT-proBNP antibody coated particles and capture reagents to qualitatively detect NT-proBNP in whole blood, serum or plasma. The minimum detection level is 0.45ng/mL.

 

 

How to use?

 

DIRECTIONS FOR USE

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

  1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
  2. Place the cassette on a clean and level surface.

For Serum or Plasma specimen:

  • Hold the dropper vertically and transfer 3 drops of serum or plasma (approximately 75 mL) to the sample well of the test cassette, then start the timer immediately. See illustration below.

For Venipuncture Whole Bloodspecimen:

  • Hold the dropper vertically and transfer 3 drops of whole blood (approximately 75 mL) to the specimen well of the test cassette, then add 1 drop of buffer (approximately 40 mL), and start the timer. See illustration below.

For Fingerstick Whole Bloodspecimen:

  • To use a capillary tube: Fill the capillary tube and transfer approximately 75 mL of fingerstick whole blood specimen to the specimen well of test cassette, then add 1 drop of buffer (approximately 40 mL) and start the timer. See illustration below.
  • To use hanging drops: Allow 3 hanging drops of fingerstick whole blood specimen (approximately 75 mL) to fall into the specimen well of test cassette, then add 1 drop of buffer (approximately 40 mL) and start the timer. See illustration below.
  1. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.

CE Certificated Rapid Diagnostic Test NT - proBNP Rapid Test Cassette 0

 

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

POSITIVE:* A colored line in the control line region (C) and the presence of another colored line in the test line regions indicates a positive result. This indicates that the concentration of NT-proBNP is above the minimum detection level.

*NOTE: The intensity of the color in the test line region will vary depending on the concentration of NT-proBNP, present in the specimen. Therefore, any shade of color in the test line region should be considered positive.

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).This indicates that the concentration of NT-proBNP are below the minimum detection levels.

INVALID:Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 