Send Message

2019-nCoV-2 IgG/IgM Test (COVID-19)

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE
Model Number: INCP-402/INCP-402S
Minimum Order Quantity: N/A
Packaging Details: 10T/25 T
Delivery Time: 10-15 days
Payment Terms: T/T
Color: Blue Specimen: Whole Blood/Serum/Plasma, Fingerstick Whole Blood Specimen
Cut Off: See Insert Storage: 2-30°C
Certificate: CE,ISO13485 Format: Cassette
High Light:

IgM Pcr Antigen Test

,

IgG Pcr Antigen Test

,

2019-NCoV Pcr Antigen Test

 

Rapid Test wue the sample of Whole Blood/Serum/Plasma With CE Mark

 

The 2019-nCoV-2 IgG/IgM Rapid Test Cassette is a lateral flow chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to 2019-nCoV-2 in human whole blood, serum or plasma specimen, and also in Fingerstick Whole Blood specimen.

 

【SUMMARY】
Early January 2020, a novel coronavirus (2019-nCoV) was identified as the infectious agent causing an outbreak of viral pneumonia in Wuhan, China, where the first cases had their symptom onset in December 2019.
Coronaviruses are enveloped RNA viruses that are distributed broadly among humans, other mammals, and birds and that cause respiratory, enteric, hepatic, and neurologic diseases.2 Six coronavirus species are known to cause human disease.3 Four viruses — 229E, OC43, NL63, and HKU1 — are prevalent and typically cause common cold symptoms in immunocompetent individuals. The two other strains — severe acute respiratory syndrome coronavirus (SARS-COV) and Middle East respiratory syndrome coronavirus (MERS-COV) — are zoonotic in origin and have been linked to sometimes fatal illness.
Coronaviruses are zoonotic, meaning they are transmitted between animals and people. Common signs of infection include respiratory symptoms, fever, cough, shortness of breath and breathing difficulties. In more severe cases, infection can cause pneumonia, severe acute respiratory syndrome, kidney failure and even death.
Standard recommendations to prevent infection spread include regular hand washing, covering mouth and nose when coughing and sneezing, thoroughly cooking meat and eggs. Avoid close contact with anyone showing symptoms of respiratory illness such as coughing and sneezing.

【DIRECTIONS FOR USE】
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.
2. Place the cassette on a clean and level surface.
For Serum or Plasma specimen:
To use a dropper: Hold the dropper vertically, draw the specimen to the fill line
(approximately 10 μL), and transfer the specimen to the specimen well (S), then add 2 drops of buffer (approximately 80 uL), and start the timer.
To use a pipette: To transfer 10 uL of specimen to the specimen well(S), then add 2 drops of buffer (approximately 80 uL), and start the timer.
For Venipuncture Whole Blood specimen:
To use a dropper: Hold the dropper vertically, draw the specimen about 1 cm above the fill line and transfer 1 full drop (approx.20 μL) of specimen to the sample well(S). Then add 2 drops of buffer (approximately 80 μL) and start the timer.
To use a pipette: To transfer 20 uL of whole blood to the specimen well(S), then add 2 drops of buffer (approximately 80 uL), and start the timer.

2019-nCoV-2 IgG/IgM Test (COVID-19) 0


For Fingerstick Whole Blood specimen:
To use a dropper: Hold the dropper vertically, draw the specimen about 1 cm above the fill line and transfer 1 full drop (approx.20 μL) of specimen to the sample well(S). Then add 2 drops of buffer (approximately 80 μL) and start the timer.
To use a capillary tube: Fill the capillary tube and transfer approximately 20 μL of fingerstick whole blood specimen to the specimen well (S) of test cassette, then add 2 drops of buffer (approximately 80 uL) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.

2019-nCoV-2 IgG/IgM Test (COVID-19) 1

 

INTERPRETATION OF RESULTS

IgG POSITIVE:* Two colored lines appear. One colored line should always appear in the control line region (C) and another line should be in the IgG line region.

IgM POSITIVE:* Two colored lines appear. One colored line should always appear in the control line region (C) and another line should be in the IgM line region.

IgG and IgM POSITIVE:* Three colored lines appear. One colored line should always appear in the control line region (C) and two test lines should be in the IgG line region and IgM line region.

*NOTE: The intensity of the color in the test line regions may vary depending on the

concentration of 2019-nCoV antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.

NEGATIVE: One colored line appears in the control line region (C). No line appears in the IgG region and IgM region.

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 