Oral fluid (MTD) Rapid Test Cassette Use by Qualitative Immunochromatographic Analyzer

Oral fluid (MTD) Rapid Test Cassette Use by Qualitative Immunochromatographic Analyzer

Brand Name: AllTest
Model Number: DMT-R802
MOQ: N/A
Price: negotiation
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Detail Information
Place of Origin:
China
Certification:
CE, ISO13485
Format::
Cassette
Specimen::
Oral Fluid
Cut-off::
30 Ng/mL
Color::
Yellow
Certificate:
CE
Kit Size::
25T
Packaging Details:
Cassette: 25pcs/Kits
Supply Ability:
10 M tests/month
Highlight:

cancer diagnostic tests

,

diagnostic blood tests

Product Description

A rapid test for the qualitative detection of ​(MTD) in human Oral Fluid that can be performed with the use of AllTestTM LF Reader. For medical and other professional in vitro diagnostic use only.

 

Application:

 

The MTD Rapid Test Cassette (Oral Fluid) is a lateral flow chromatographic immunoassay for the detection of in human urine that can be performed with the use of AllTestTM LF Reader at a cut-off concentration of 30ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.

This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Description:

 

is a narcotic analgesic prescribed for the management of moderate to severe pain and for the treatment of opiate dependence (, Vicodin, Percocet, morphine).
is a long acting pain reliever producing effects that last from twelve to forty-eight hours. Ideally, frees the client from the pressures of obtaining illegal , from the dangers of injection, and from the emotional roller coaster that most opiates produce. , if taken for long periods and at large doses, can lead to a very long withdrawal period. The withdrawals from are more prolonged and troublesome than those provoked by cessation, yet the substitution and phased removal of is an acceptable method of detoxification for patients and therapists.

 

How to use?

 

Allow the test cassette, specimen, and/or controls to reach room temperature (15-30ºC) prior to testing. Instruct the donor to not place anything in the mouth including food, drink, gum or tobacco products for at least 10 minutes prior to collection.
1.Exact QR Code from the QR code card for specific information of the test. Use only QR code card provided inside the test kits.
2.Bring the pouch to room temperature before opening it. Remove the test from the sealed pouch and use it within one hour.
3.Remove the collector from the sealed pouch and collect oral fluid specimen as follows:
Important: Place the tongue against the upper and lower jaws and roots to enrich the oral fluid before oral fluid collection.
Insert the sponge end into the mouth, actively swab around the gums on both sides of the mouth and under the tongue and chew the sponge tenderly, place the sponge end under the tongue for a total of 2-3 minutes until the sponge becomes fully saturated.
Gently pressing the sponge between the tongue and teeth will assist saturation. No hard spots should be felt on the sponge when saturated.
4.Remove the collector from the mouth. Place saturated oral fluid collector into collection tube and press sponge fully against the strainer to collect oral fluid. Discard the collector. Snap the cap shut on the Collection tube.
5.Place the test cassette on a clean and level surface. Unscrew cap cover from the Collection tube. Invert the Collection tube and transfer 3 drops of oral fluid (approximately 120 µL) into specimen well of the test cassette. Avoid trapping air bubbles in the specimen well. Place screw cap on the collection tube. Wait for the flow to appear in the test windows and start the timer.
6.The Results should be Read with AllTestTM LF Reader at 10 minutes.
7.Do not interpret test results visually.
8.Apply the security seal over screw cap and send to the laboratory for confirmation if necessary.
 
Oral fluid   (MTD) Rapid Test Cassette Use by Qualitative Immunochromatographic Analyzer 0
 

INTERPRETATION OF RESULTS


Results read by Alltest LF reader


The result of positive or negative for C-reactive Protein (CRP) is determined by the Alltest LF reader.


Result could be exported to excel.

 
Cat No. Description Specimen Cut-off Value
DMT-R802 (MTD) Rapid Test Cassette(oral fluid) Oral Fluid 30 ng/mL