VIAIH-507 Avian Influenza Virus AIV H5 Rapid Test Kit Veterinary Diagnosis Antigen Test Kit

Basic Information
Brand Name: VECHECK
Model Number: VIAIH-507
Product Name: Avian Influenza Virus H5 (AIV H5) Antigen Rapid Test Test Format: Cup
Test Kit Shelf Life: 24 Months Test Kit Size: 10 T
Test Kit Storage Condition: 2-30℃ Test Method: Immunochromatography
Test Sample: Laryngotracheal Secretion/Feces Test Time: 10 Minutes
Test Type: Rapid Test
Highlight:

Veterinary Avian Influenza Virus Test Kit

,

AIV H5 Rapid Test Kit

,

AIV H5 Diagnostic Test Kit

Avian Influenza Virus H5 (AIV H5) Antigen Rapid Test
(Laryngotracheal secretion/Feces)
VIAIH-507
 
 
INTENDED USE
The Avian Influenza Virus H5 (AIV H5) Antigen Rapid Test (Laryngotracheal secretion/Feces) is a sandwich lateral flow immunochromatographic assay for qualitative detection avian influenza H5 virus in avian trachea and feces to auxiliary diagnosis of avian influenza H5 virus infection, such as chicken, bird and duck.
For veterinary use only.
 
PRINCIPLE
The Avian Influenza Virus H5 (AIV H5) Antigen Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test has a testing window with an invisible T (test) zone and C (control) zone. During testing, the liquid will laterally flow on the surface of the test strip. If there is enough avian influenza H5 virus antigens in the sample, a visible T line will appear. The C line should always appear after a sample is applied, indicating a valid result. By this means, the test can accurately indicate the presence of avian influenza H5 virus antigen in the sample.
 
STORAGE AND STABILITY
Store as packaged in the sealed pouch either at room temperature or refrigerated (2-30 °C). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE.
Do not use beyond the expiration date.
 
PRECAUTIONS
 Do not use after the expiration date. Do not reuse the test kit.
 Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens.
 Wear disposable gloves and eye protection when specimens are being tested.
 Humidity and temperature can adversely affect results.
 Do not remove test from its pouch until immediately before use.
 Do not mix components from different lot and different products.
 Please ensure that an appropriate amount of samples are used for testing. Too much or too little sample size may lead to deviation of results.
 
MATERIALS
Materials Provided
• Test Cups (with dilution buffer)
• Swabs
• Package Insert
Materials Required But Not Provided
• Timer
DIRECTIONS FOR USE
Allow the test and specimen to equilibrate to room temperature (15-30 °C) prior to testing.
1. Remove the test from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Unscrew the cap of the test cup.
Collect animal’s laryngotracheal secretion with a swab or collect animal’s feces with the swab from the anus. Insert the wet swab into the test cup and mix well. Remove the swab.
Collect animal’s feces with the collection applicator on the ground. Randomly stab the specimen collection applicator into the specimen in at least 3 different sites to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). Do not scoop the fecal specimen.
3. Insert the specimen collection applicator back into the test cup and tighten the cap.
4. Shake the test cup for about 10-15 seconds to mix well. Leave the cup for reaction for 2 minutes.
5. Remove the plastic limit strip of the test cup.
6. Put the test cup on a clean and level surface, press the cup body from the top to the bottom and start the timer.
Note: Keep the test upright while testing. Do not move or turn the test upside down.
7. Read the result at 10 minutes. Do not interpret results after 15 minutes.
 
INTERPRETATION OF RESULTS
Positive: The presence of both C line and T line, no matter T line is clear or
vague.
Negative: Only clear C line appears.
Invalid: No colored line appears in C zone, no matter whether T line appears.