Send Message

TAP Tapentadol Rapid Test Dipstick Detection In Human Urine

Basic Information
Place of Origin: China
Brand Name: ALLTEST
Certification: CE
Model Number: DTAP-111/101
Minimum Order Quantity: N/A
Price: negotiation
Packaging Details: 50T
Delivery Time: 2-4 Weeks
Supply Ability: 10 M tests/month
Product: TAP-Tapentadol Rapid Test Dipstick , Detection Of Tapentadol In Human Urine, Drugs Of Abuse Brand: AllTest
Cat No.: DTAP-101/111 Principle: Chromatographic Immunoassay
Format: Dipstick Specimen: Urine
Certificate: CE Reading Time: 5 Minutes
Pack: 50T Storage Temperature: 2-30°C
Shelf Life: 2 Years Sensitivity: 94.4%
Specificity: 98.2% Accuracy: 96.7%
Cut-Off: 500 Ng/mL FEATURES: Convenient Operation
High Light:

TAP Tapentadol Rapid Test Dipstick

,

TAP Tapentadol Drug Abuse Test Kit

TAP-Tapentadol Rapid Test Dipstick , detection of Tapentadol in human urine, drugs of abuse

 

Application

 

Product: TAP-Tapentadol Rapid Test Dipstick , Detection Of Tapentadol In Human Urine, Drugs Of Abuse
Cat No.: DTAP-101/111
Format: Dipstick
Certificate: CE
Pack: 50T
Shelf Life: 2 Years
Specificity: 98.20%
Cut-Off: 500 Ng/mL
Brand: AllTest
Principle: Chromatographic Immunoassay
Specimen: Urine
Reading Time: 5 Minutes
Storage Temperature: 2-30°C
Sensitivity: 94.40%
Accuracy: 96.70%
FEATURES:

Convenient Operation

 
A rapid test for the qualitative detection of Tapentadol in human urine. For professional in vitro diagnostic use only.
 
The TAP Rapid Test Dipstick (Urine) is a rapid chromatographic immunoassay for the detection of Tapentadol in human urine at a cut-off concentration of 1000 ng/mL. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.
 
This assay provides only a qualitative preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.
 
PRINCIPLE
 
The TAP Rapid Test Dipstick (Urine) is a rapid chromatographic immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, a urine specimen migrates upward by capillary action. Tapentadol, if present in the urine specimen below 1000 ng/mL, will not saturate the binding sites of the antibody coated particles in the test. The antibody coated particles will then be captured by immobilized Tapentadol conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Tapentadol level exceeds 1000 ng/mL because it will saturate all the binding sites of anti-Tapentadol antibodies. A drug-positive urine specimen will not generate a colored line in the test line region, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
 
PRECAUTIONS
• For professional in vitro diagnostic use only. Do not use after the expiration date.
• The test should remain in the sealed pouch until use.
• All specimens should be considered potentially hazardous and handled in the same manner as an infectious agent.
• The used test should be discarded according to local regulations.
 
DIRECTIONS FOR USE
Allow the test, urine specimen, and/or controls to reach room temperature (15-30 ºC) prior to testing.
 
1. Bring the pouch or canister to room temperature before opening it. Remove the test dipstick from the sealed pouch or closed canister and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the test dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
 
TAP Tapentadol Rapid Test Dipstick Detection In Human Urine 0
 
QUALITY CONTROL
 
A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique. Control standards are not supplied with this kit; however, it is recommended that positive and negative controls be tested as good laboratory testing practice to confirm the test procedure and
to verify proper test performance.
 
EXPECTED VALUES
 
This negative result indicates that the Tapentadol concentration is below the detectable level of 1000 ng/mL. Positive result means the concentration of Tapentadol is above the level of 1000 ng/mL. The TAP Rapid Test Dipstick (Urine) has a sensitivity of 1000 ng/mL.

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852