Send Message

Ferritin Rapid Test Reader Diagnostic Test Cassette CE Mark Long Life

Basic Information
Place of Origin: China
Brand Name: Alltest
Certification: CE
Model Number: Cassette (OCAL-R602)
Packaging Details: 1 T/Box
Delivery Time: 20Days
Color: White Specimen: Whole Blood/Serum/Plasma
Format: Cassette Kit Size: 10T
Cut-off: See Insert Certificate: CE
High Light:

anesthesia devices

,

medical product

High quality Ferritin Rapid Test Diagnostic Test Cassette CE Mark

 

Application:

 

Description:

 

The Ferritin Rapid Test Cassette (Whole Blood/Serum/Plasma) is a quantitative, lateral flow immunoassay for the detection of human ferritin in human serum or plasma and whole blood. The membrane is precoated with anti-ferritin polyclonal antibody on the test line region. And the membrane is precoated with Goat anti Rabbit IgG on the reference line region. The gold is precoated with anti-ferritin monoclonal antibody and Rabbit IgG. During testing, the specimen reacts with the particle coated with anti-ferritin monoclonal antibody. The mixture migrates upward on the membrane chromatographically by capillary action to react with anti-ferritin polyclonal antibody on the membrane and generate a colored line. The line in test line region (T) appears, if the ferritin level exceeds the cut-off level of 13ng/ml. If the ferritin concentration is less than 13ng/ml, the test line not appears. To serve as a procedural control, a colored line will always appear in the control line region, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

 

How to use?
 
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
Exact QR Code from the QR code card for specific information of the test. Use only QR code card provided inside the test kits.
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30℃) before opening it. Remove the cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 full drop of serum or plasma (approximately 25μL) to the specimen well of the cassette, then add 1 drop of buffer (approximately 40μL) and start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. The result should be read with AllTestTM LF Reader at 5 minutes.
4. Do not interpret test results visually.
5. For AllTestTM LF Reader installation, start up and complete instructions refer to AllTestTM LF Reader User Manual. Operator must consult AllTestTM LF Reader User Manual prior to use and become familiar with the processes and quality control procedures.
 
Ferritin Rapid Test Reader Diagnostic Test Cassette CE Mark Long Life 0
 
For whole blood specimen:
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2. Place the cassette on a clean and level surface.
For Venipuncture Whole Blood specimen:
Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50μL) to the specimen well, then add 1 drop of buffer (approximately 40μL), and start the timer. See illustration below.
 
For Fingerstick Whole Blood specimen:
To use a capillary tube: Fill the capillary tube and transfer approximately 50μL of fingerstick whole blood specimen to the specimen well of test cassette, then add 1 drop of buffer (approximately 40μL) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear. The result should be read with AllTestTM LF Reader at 5 minutes.
4. Do not interpret test results visually.
5. For AllTestTM LF Reader installation, start up and complete instructions refer to AllTestTM LF Reader User Manual. Operator must consult AllTestTM LF Reader User Manual prior to use and become familiar with the processes and quality control procedures.
Ferritin Rapid Test Reader Diagnostic Test Cassette CE Mark Long Life 1
 
 
INTERPRETATION OF RESULTS

Results read by the AlltestTM LF Reader
The result of positive or negative for calprotectin is determined by AlltestTM LF Reader.
Result could be exported to excel or PDF. Other clinically available tests are required if questionable results are obtained.
 

Contact Details
selina

Phone Number : +8615857153722

WhatsApp : +8613989889852