Mephedrone Drug Abuse Test Kit One Step Rdt Test Kit High Sensitivity Use Simple

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: DMEP-101/DMEP-102/DMEP-114
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 40T/Kit,50T/Kit
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette/Strip/Panel Color: Yellow
Certificate: CE Specimen: Urine
Cut-Off: 100 Ng/mL Kit Size: 40T/Kit,50T/Kit
High Light:

rapid diagnostic test kits

,

one step rapid test

 

Human Urine Mephedrone High Sensitivity One Step ​Rapid Test Kits For 

 

Applications And Description: 

 

Mephedrone, also known as 4-methylmethcathinone (4-MMC) or 4-methylephedrone is a synthetic stimulant drug of the amphetamine and cathinone classes. Slang names includedrone, M-CAT, White Magic and meow meow.It is chemically similar to the cathinonecompounds found in the khat plant of eastern Africa.
Mephedrone comes in the form of tablets or a powder, which users can swallow, snort or inject,producing similar effects to MDMA, amphetamines and cocaine. In addition to its stimulant effects, mephedrone produces side effects, of which teeth grinding are the most common.

 

How to use? 

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

 

Mephedrone Drug Abuse Test Kit One Step Rdt Test Kit High Sensitivity Use Simple 0

 

【DIRECTIONS FOR PANEL USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Remove the test panle from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but
do not touch the plastic device.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

Mephedrone Drug Abuse Test Kit One Step Rdt Test Kit High Sensitivity Use Simple 1

【DIRECTIONS FOR DIPSTICK USE】
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

Mephedrone Drug Abuse Test Kit One Step Rdt Test Kit High Sensitivity Use Simple 2

 

INTERPRETATION OF RESULTS

 

(Please refer to the illustration above)

 

NEGATIVE:* Two lines appear. One color line should be in the control region (C), and another apparent color line should be in the test region (T). This negative result indicates that the Tramadol (TML) concentration is below the detectable cutoff level.

 

*NOTE: The shade of color in the test region (T) may vary, but it should be considered negative whenever there is even a faint color line.

 

POSITIVE: One color line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the Tilidine (TLD) concentration is above the detectable cutoff level.

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test Dipstick. If the problem persists, discontinue using the test Dipstick immediately and contact your local distributor.

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DMEP-102 Mephedrone HCI (MEP) Rapid Test Cassette Urine Cassette 40 T 100 ng/mL* CE
DMEP-114 Mephedrone HCI(MEP) Rapid Test Panel Urine Panel 40 T CE
DMEP-101 Mephedrone HCI(MEP) Rapid Test Dipstick Urine Dipstick 50 T CE