No Cross Reactivity 25ng/ml PCP Drug Abuse Test Kit whole blood /serum /plasma Phencyclidine Diagnosis OEM

Basic Information
Place of Origin: China
Brand Name: AllTest
Certification: CE, ISO13485
Model Number: Cassette
Minimum Order Quantity: N/A
Price: Negotiation
Packaging Details: 40 cassette/box
Delivery Time: 2-4 Weeks
Payment Terms: Ex works
Supply Ability: 10 M tests/month
Format: Cassette Specimen: WB/S/P
Kit Size: 40T/Kit Storage: 2-30℃
Color: White Certificate: CE
Cut-off: 20 Ng/ml
High Light:

rapid diagnostic test kits

,

home drug test kits

No Cross Reactivity 25ng/ml PCP Drug Abuse Test Kit whole blood /serum /plasma Phencyclidine Diagnosis OEM

 

Applications: 

 

The PCP Rapid Test Cassette (whole blood/serum/plasma) is a lateral flow chromatographic immunoassay for the detection of Phencyclidine in whole blood or serum or plasma at a cut-off concentration of 20ng/ml. This test will detect other related compounds, please refer to the analytical Specificity table in this package insert.
This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are
used.

 

Description:

 

Phencyclidine, also known as PCP, is a hallucinogen that was first marketed as a surgical anesthetic in the 1950’s. It was removed from the market because patients receiving it became delirious and experienced hallucinations.
Phencyclidine is used in powder, capsule, and tablet form. The powder is either snorted or smoked after mixing it with marijuana or vegetable matter. PCP is most commonly administered by inhalation but can be used intravenously, intra-nasally, and orally. After low doses, the user thinks and acts swiftly and experiences mood swings from euphoria to depression. Self-injurious behavior is one of the devastating effects of PCP.

 

How to use?

 

 

Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
 
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30℃) before opening it. Remove the cassette from the sealed pouch and use it within one hour.
2. Place the cassette on a clean and level surface. Hold the dropper vertically and transfer 1 full drop of serum or plasma (approximately 40μl), then add 2 drops of buffer (approximately 80μl) to the specimen well of the cassette, and then start the timer. Avoid trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not interpret the result after 10 minutes.
 

No Cross Reactivity 25ng/ml PCP Drug Abuse Test Kit whole blood /serum /plasma Phencyclidine Diagnosis OEM 0

 

For whole blood specimen:
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
2. Place the cassette on a clean and level surface.
For Venipuncture Whole Blood specimen:
 Hold the dropper vertically and transfer 1 drop of whole blood(approximately 40μl) to the specimen well, then add 2 drops of buffer (approximately 80μl), and start the timer. See illustration below.
For Fingerstick Whole Blood specimen:
 To use a capillary tube: Fill the capillary tube and transfer approximately 40μl of fingerstick whole blood specimen to the specimen area of test cassette, then add 2 drops of buffer(approximately 80μl) and start the timer. See illustration below.
3.Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
 

No Cross Reactivity 25ng/ml PCP Drug Abuse Test Kit whole blood /serum /plasma Phencyclidine Diagnosis OEM 1

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the Phencyclidine concentration is below the detectable cut-off level.


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.
POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the Phencyclidine concentration exceeds the detectable cut-off level.


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 